Intertek Directory of Building Products

SAFTI FIRST 20 Min - 3 Hour Steel Fire Door (Single Swing/Standard Pairs/Double Egress/Dutch) Company: SAFTI FIRST

Hollow Metal Type (16 gauge), Swinging Flush Design Fire Door for installation singly or in pairs (including Double Egress) in 20 minute to 3 hour locations.

Limitations: Cylindrical Latches/Mortised Top and Bottom Bolts/Temp. Rise 250°F @ 30 minutes/Ball bearing Hinges permitted/Stainless steel cladding permitted.  Stainless steel, brass, or aluminum cladding - (aluminum and brass cladding not permitted on meeting edges of pairs).
 
Maximum Size of Openings: 1-1/2 hr. Singles - 4'6" wide x 10'0" high
3 hr. Singles - 4'0" wide x 8'0" high
1-1/2 hr. Standard Pairs - 8'0" wide x 10'0" high
3 hr. Standard Pairs - 8'0" wide x 8'0" high
1-1/2 hr. Double Egress Pairs - 8'0" wide x 10'0" high

Note: Doors - 10'0"

Hollow Metal Type (16, 18 gauge) (Steel-Faced) (Vertically-Stiffened) (Insulated), Swinging Flush Design Dutch Doors for installation in single swing 20 minute to 3 hour locations.

Limitations: Mortise or Cylindrical Latches/Minimum Bolt Throw - 3/4"/Minimum Backset - 5", Mounted on the Bottom Leaf, Latching into the Door Frame or Top Leaf. OR Mortise or Cylindrical Latches/Minimum Bolt Throw - 3/4"/Maximum Backset - 5"/Mounted on the Top Leaf/Latching into the Bottom Leaf or Door Frame. OR Flat Bar Astragal/2" wide x 1/8" thick x length ( = door width) must be used on the Top Leaf at the Meeting Edge / Stainless steel or aluminum cladding permitted on door face.
 
Maximum Size of Openings: 4'0" wide x 8'0" high

Fire Resistive Glass allowed up to the maximum size tested per glazing and vision kit manufacturers listings.  Glass must be listed for fire door applications (UL 10B, UL10C, NFPA 252, and/or CAN/ULC S104) in the sizes specified.  Vision kit must be listed for use with this type of glass and up to the sizes specified.

Fire Protective Glass allowed in 20 - 45 minute doors allowed per glazing and vision kit manufacturers listings.

Fire Protective Glass in 60 - 180 Minute Doors: 100in2

Evaluated to the following:
Unless otherwise noted, assemblies in this section have been evaluated for conformance to the following standards:
CAN/ULC-S104, Standard Method for Fire Tests of Door Assemblies
NFPA-252, Standard Methods for Fire Tests of Door Assemblies
UL-10(b), Fire Tests of Door Assemblies
UL-10(c),  Positive Pressure Fire Tests of Door Assemblies
and are installed in accordance with the following:
NFPA-80, Fire Doors and Windows


The door noted above is eligible to bear the "S" (for Smoke & Draft Control assemblies) if a listed "Category H - Smoke & Draft Control Gasket" has been applied to the assembly. Please refer to Category H for individual gasket manufacturer's listings.

Manufacturer's Instructions.
All assemblies are identified by a label or marking bearing the wording, "Listed (Product)", a time interval, temperature rise (if applicable), a serial number and the WHI Certification Mark.
(Unless otherwise specified, all Fire Doors have a nominal thickness of 1-3/4".)
Listing Report Certificate of Compliance Return to Search
Attributes
Certificate Date of ExpiryDecember 31, 2026
Certificate Date of Initial RegistrationSeptember 1, 2017
Certificate NumberWHI18-20840001
CriteriaUL 10(b) 2008 (R2009)
CriteriaCAN / ULC S104 (2010)
CriteriaNFPA 252 (2012)
CriteriaUL 10(c) (2009) (R2015)
CSI Code08 11 13 Hollow Metal Doors and Frames
Fire Resistance45 Min Neutral Pressure
Fire Resistance90 Min Neutral Pressure
Fire Resistance3 Hour Neutral Pressure
Fire Resistance60 Min Neutral Pressure
Fire Resistance45 Min Positive Pressure
Fire Resistance90 Min Positive Pressure
Fire Resistance60 Min Positive Pressure
Fire Resistance3 Hour Positive Pressure
Fire Resistance20 Min Neutral Pressure
Fire Resistance20 Min Positive Pressure
Listing SectionDOORS
Spec ID42263
SwingSingle Swing
SwingStandard Pairs
SwingDutch
SwingDouble Egress
Design Documents
No Results
Public Documents
No Results