Intertek Directory of Building Products

Kingspan - KS Series, Optimo, and Karrier Panels Company: Kingspan Insulated Panels Inc. Code Compliance Research Reports: CCRR-1074

PRODUCT DESCRIPTION

KS Series, Optimo and Karrier panels are metal faced, foam insulated wall panels. The core of the panels consists of PIR or Quadcore foam that is continuously poured-in-place between the metal skins.  The panels have a dual tongue and groove joint stacked one over the other and are formed with a “C” shaped 1/4-inch diameter nosing. The interior joint is filled with a non-skinning butyl sealant. As an option, the exterior joint can also be filled with sealant. The panels are attached directly to supporting structure using hidden-fix fasteners.

KS Series, Optimo and Karrier panels with exterior skin thickness of 22 gauge and interior skin thickness of 24 gauge are produced in panel thicknesses of 2, 2-1/2, 3 and 4 inches.  The standard panel widths are 24, 30 and 36 inches.   The metal facings are most commonly painted.  The primary application is architectural walls.  
 
KS Series, Optimo and Karrier panels with interior and exterior skin thickness of 26 gauge are produced in panel thicknesses of 2, 2-1/2, 3, 4, 5 and 6 inches with panel width of 24, 30, 36, 40 and 42 inches.   The metal facings are painted. The primary applications include walls, roofs and cold storage. 

Kingspan Manufacturing Plants
 
Location Products
Caledon, ON All
Langley, BC All
Modesto, CA All
Deland, FL All


RATINGS
 
Evaluation Method Building Code CCRR Number
ICC-ES AC04
AC05
AC12     
2024, 2021, 2018  International Building Code
2023 Florida Building Code (excluding HVHZ)
2022 California Building Code
2023 City of Los Angeles Building Code
CCRR-1074
 
Test Standard Rating Design Number
NFPA 285  Conforms    
KIP/IMWP 30-03 (KS Series)
KIP/IMWP 30-04 (Optimo)
 

 
Listing Report Return to Search
Attributes
CriteriaICC-ES AC04 (2012)
CriteriaICC-ES AC12 (2015) rev. 2016
CriteriaNFPA 285 (2019)
CriteriaICC-ES AC04 (2019)
CSI Code07 40 00 Roofing and Siding Panels
CSI Code07 42 13 Metal Wall Panels
CSI Code07 42 13.19 Insulated Metal Wall Panels
Listing SectionBUILDING PANELS
Spec ID43137
Design Documents
Code Compliance Research Reports
Public Documents
No Results