Intertek Directory of Building Products

GacoOnePass Low GWP F1880/F1880W Spray-applied Polyurethane Insulation Company: Gaco, a division of Holcim Solutions and Products US, LLC Code Compliance Research Reports: CCRR-1106

GacoOnePass Low GWP F1880 and GacoOnePass Low GWP F1880W insulations are closed cell, medium-density, polyurethane foam plastics.  The insulations are two-component, spray-applied foam plastics with a nominal in-place density of 2.2 pcf.  The insulations are produced in the field by combining a polymeric isocyanate (A component) with a resin (B component).  The insulation liquid components are supplied in 55-gallon drums and 250-gallon totes, and must be stored at temperatures between 40°F and 80°F.  The resin (B component) must be protected from freezing temperatures.  The insulation has a shelf life of 6 months on the polymeric isocyanate (A component) and 5 months on the resin (B component) when stored in factory-sealed containers at these temperatures.

FLAME SPREAD RATINGS
Test Standard Flame Spread Smoke Development
ASTM E84 25 or less 450 or less

FIRE RATINGS
Test Standard Rating Design Number
NFPA 285 Meets the requirements GWL/FI 30-04
NFPA 285 Meets the requirements GWL/FI 30-05
NFPA 285 Meets the requirements GWL/FI 30-07

CODE COMPLIANCE RESEARCH REPORT
Evaluation Method Building Code CCRR Number
ICC-ES AC377 2024, 2021, 2018, and 2015
IBC, IRC, and IECC
CCRR-1106
Listing Report Return to Search
Attributes
CriteriaICC-ES AC377 (February 2020)
CriteriaICC 1100 (2019)
CriteriaASTM E84 (2021a)
CriteriaNFPA 285 (2023)
CSI Code07 21 00 Thermal Insulation
CSI Code07 21 19 Foamed-In-Place Insulation
Listing SectionBUILDING MATERIALS WITH SURFACE BURNING CHARACTERISTICS
Listing SectionFOAM PLASTIC INSULATION
Spec ID43195
Design Documents
Code Compliance Research Reports
Public Documents
No Results