Products Covered
Stainless Steel Single Swing Doors and Stainless Steel Pair Doors
Ratings
Single Swing Door Ratings
The door assemblies are designed for the protection of openings in walls for up to and including 3 hour locations. (See limitations below.) This product is listed for fire resistance only.
Pair Door Ratings
The door assemblies are designed for the protection of openings in walls for up to and including 90 minute locations. (See limitations below.) This product is listed for fire resistance only.
Limitations
Hardware Limitations: Cylindrical / Cylindrical with Deadbolt / Mortise / Card Reader / Surface-Mounted or Concealed Vertical Rod Fire Exit Devices / Rim-Type Surface Mounted Fire Exit Devices / Surface or Mortise Flush Bolts / Surface Mounted or Mortised Door Bottoms / Surface Mounted or Concealed Closers / Viewers / Raceway / EPT / Magnetic Switch / Plant-Ons / Protection Plates / Louver / Vision Kit.
Single Swing Door Limitations:
| Application (min) |
20-45 |
60-180 |
| Configuration |
Single |
Single |
| Maximum Size |
4'0" x 8'0" |
4'0" x 8'0" |
| Latch Throw Req. |
5/8" |
3/4" |
| Latching |
Single Point |
Single Point |
| Core |
Honeycomb or Fiberglass (Positive Pressure)
EPS Foam (Neutral Pressure) |
Honeycomb or Fiberglass (Positive Pressure)
EPS Foam (Neutral Pressure) |
| Edge Seam |
Interlock Seam, Overlap Joint Seam, Lap Joint Seam, Butt Edge Seam |
Interlock Seam, Overlap Joint Seam, Lap Joint Seam, Butt Edge Seam |
Pair Door Limitations:
| Application (min) |
20 |
45-90 |
| Configuration |
Pair |
Pair |
| Maximum Size |
8'0" x 8'0" |
8'0" x 8'0" |
| Latch Throw Req. |
5/8" |
3/4" |
| Latching |
Minimum 3 Point (Single Point on Active and Two Point [Top and Bottom] on Inactive) |
Minimum 3 Point (Single Point on Active and Two Point [Top and Bottom] on Inactive) |
| Astragal Required |
No |
Yes |
| Type of Astragal |
N/A |
Flat, Z or H |
| Core |
Honeycomb or Fiberglass (Positive Pressure)
EPS Foam (Neutral Pressure) |
Honeycomb or Fiberglass (Positive Pressure)
EPS Foam (Neutral Pressure) |
| Edge Seam |
Interlock Seam, Overlap Joint Seam, Lap Joint Seam, Butt Edge Seam |