Intertek Directory of Building Products

American Steel Products 20-180 Min. Fire Door Frame Company: Coastal Plain Ventures, LLC dba American Steel Products

Pressed Steel Door Frame (16, 14, 12 gauge) (Welded Up or Knocked Down) for installation singly or pairs (including Double Egress) in 20, 45, 60, 90, 180 minute steel/wood stud drywall or masonry openings.

 

Maximum size of openings: 8'0" wide x 10'0" high w/o transom panel
8'0" wide x 12'0" high w/transom panel of same rating as door

Pressed Steel Door Frame (16, 14, 12 gauge) (Welded Up) for installation singly or pairs (including Double Egress) in 20, 45, 60, 90 minute steel/wood stud drywall or masonry openings with side panels.

 
Maximum size of openings: 12'0" wide x 10'0" high

Pressed Steel Door Frame (16, 14, 12 gauge) (Welded Up) for installation singly in 20, 45, 60, 90 minute steel/wood stud drywall.

Maximum size of openings: 3'6" wide x 7'0" high w/o transom panel

Pressed Steel Door Frame (16, 14, 12 gauge) (Welded Up) for installation singly or pairs (including Double Egress) in 20, 45 minute steel/wood stud drywall or masonry openings with transom lights and/or side lights.

Maximum size of openings: 12'0" wide by 12'0" high
Maximum individual visible area of glazing panel: 1,296 sq.in.
Maximum visible width of glazing panel: 48"
Height of glazing panel: 54"
Limitations:
Door stop depth: 5/8"
Depth of grooves for lights:
Visible Area
Groove Depth
 
300 sq.in. 1/2"
 
400 sq.in. 9/16"
 
500 sq.in. 5/8"
 
600 sq.in. 11/16"
 
1296 sq.in. 3/4"


Evaluated to the following...

Unless otherwise noted, assemblies in this section have been tested to the following standards:

ASTM-E152, Methods of Fire Tests of Door Assemblies;
CAN4-S104(ULC-S104), Standard Method for Fire Tests of Door Assemblies;
CSFM-43.7, Methods of Fire Tests of Door Assemblies;
NFPA-252, Standard Methods of Fire Tests of Door Assemblies;
UBC-7-2-94, Uniform Building Code;
UL-10(b), Fire Tests of Door Assemblies;

and are installed, unless otherwise noted, in accordance with the following:

NFPA-80, Fire Doors & Windows.
Manufacturer's Instructions.

Listed maximum sizes of lights are based on sizes tested and may exceed local code requirements.

All frames are identified by either a label or embossed marking bearing the wording "Listed (Product)" and the WHI Certification Mark. Frames rated for less than 3 hours also bear the time interval. Frame labels that do not include a time interval are rated for 3 hours.

Listing Report Return to Search
Attributes
CriteriaCAN4 S104 (1985)
CriteriaNFPA 80 (2007)
CriteriaNFPA 252 (2008)
CriteriaUL 10(b) (2008) (R2009)
CriteriaNFPA 252 (2012)
CriteriaUL 10(c) (2016)
CriteriaUL 10(b) (2008) (R2015)
CSI Code08 11 00 Metal Doors and Frames
Fire Resistance20 Min NP Fire Doorframe
Fire Resistance45 Min NP Fire Doorframe
Fire Resistance60 Min NP Fire Doorframe
Fire Resistance3 Hour NP Fire Doorframe
Fire Resistance90 Min NP Fire Doorframe
Fire Resistance90 Minute Fire Rated
Listing SectionDOOR FRAMES