PRODUCT COVERED
Warm Springs 60 Minute Fire Resisting Doorsets are wood/mineral composite doors for use in fire rated applications per BS 476 Part 22 (1987) for insulation and integrity ratings as specified below
Insulation: See the table and glazing restrictions below. Insulation rating is dependent on glazing configuration (See Machining Information section of this listing for complete approvals, restrictions, and limitations)
Type |
Details |
Fully Insulating |
Mineral Composite (Tectonite) or Hardwood |
Unglazed doorsets |
Integrity: 60 Minutes
MAXIMUM SIZES AND RATINGS
Allowable Configuration(s) |
Maximum Leaf Size (mm) [h x w]* |
Frame Type |
Glazing |
Overpanel |
Insumescent Required |
LSASD |
From: 2292 x 1677
To: 3588 x 1068 |
Mineral Composite (Tectonite) or Hardwood
|
Yes
|
Yes (Max. Height 500 mm)
|
Yes (WSCP)
|
ULSASD |
From: 2292 x 1652
To: 3538 x 1068 |
DASD |
From: 2292 x 1652
To: 3538 x 1068 |
LSADD |
From: 2292 x 1627
To: 3488 x 1068 |
ULSADD |
From: 2292 x 1602
To: 3438 x 1068 |
DADD |
From: 2292 x 1602
To: 3438 x 1068 |
*Smaller leaf sizes allowed.
Please note: Consult Manufacturing and Machining sections of this listing for hardware and instumescent requirements.
DEFINITION KEY
LSASD - Latched Single Acting Single Doorset
ULSASD - Unlatched Single Acting Single Doorset
DASD - Double Acting Single Doorset
LSADD - Latched Single Acting Double Doorset
ULSADD - Unlatched Single Acting Double Doorset
DADD - Double Acting Double Doorset
Please consult Intertek or Warm Springs with any questions that pertain to the door construction referenced within this listing.