Lexington Fire Shield 90 Min. Flush Fire Door Company: Lexington Manufacturing, LLC

FIRE RESISTANT PRODUCTS & COMPONENTS
CATEGORY A DOORS - NO ADDITIONAL EDGE-SEALING SYSTEM REQUIRED
Category "A" Wood Composite Core, swinging door for use in 20 through 90 minute positive pressure assemblies (also eligible for use in neutral pressure assemblies). 

CATEGORY B DOORS - ADDITIONAL EDGE-SEALING SYSTEM REQUIRED
Category "B" Wood Composite Core, swinging door for use in 20 through 90 minute positive pressure assemblies (also eligible for use in neutral pressure assemblies).  A surface applied Category G intumescent edge seal system is required.

PRODUCT COVERED
Lexington Fire Shield 90 Min. Flush Fire Door

PRODUCT DESCRIPTION
Hardware Limitations:  Cylindrical / Cylindrical with Deadbolt / Mortise / Card Reader / Surface-Mounted Vertical Rod Fire Exit Devices / Rim-Type Surface Mounted Fire Exit Devices / Surface Bolts or Mortised Flush Bolts / Surface Mounted or Concealed Door Bottoms / Surface Mounted or Concealed Closers or Overhead Stops / Viewer / Vision Kit - Max. 100 sq. in./ 960 sq. in temp rise glazing/ 2176 sq. in. 45 minute / Raceway / EPT / Plant-Ons / Protection Plates / Reveals and Inlays.

Configuration                   Maximum Size
Single                              4'0" wide x 9'0" high

Standard Pair                 See Table below.

Double Egress                 See Table below.

 
Duration (minutes) Maximum    size
(w x h)
Swing   Latching   Metal  Edge
(5") 
Comments
90 8'0" by 9'0" Std Pair SVR/LBR    
2 Pt.
No Requires Thermal Pin door to Door and MD Core
90 8'0" by 8'0" Std Pair SVR    
4 Pt.
No None
90 8'0" by 9'0" Std Pair 3 Pt. latching Auto or manual flushbolts No Cylindrical or Mortise minimum 1/2" throw
90 8'0" by 8'0 Double
Egress
SVR/LBR No Requires 2 thermal pins door to door & HD Core
90 8'0" by 7'0" Double Egress SVR/LBR No Requires 2 thermal pins door to door
90 8'0" by 8'0 Double Egress SVR    
4 pt.
No Must have top and bottom rod Hardware
90 8'0" by 8'0 Double Egress CVR/CVC
2 pt.
Yes Requires thermal pin door to door
90 8'0" by 7'0" Double Egress CVR / SVR
2 pt.
Yes No pin
90 6'0" by 9'0" Std. Pair CVR 4 pt. Yes Bottom latches required.
90 8'0" by 7'0" Std. Pair CVR 2 pt. Yes No
90 8'0" by 7'0" Std. Pair SVR 2 pt. No Thermal pins not required 
60 8'0" by 8'0 Double
Egress
SVR/LBR No Requires  Thermal pin door to door & MD Core
60 8'0" by 7'0" Double Egress SVR/LBR No Thermal pins not required
60 8'0" by 9'0" Std. Pair SVR
2 pt.
No Requires  thermal pin door to door & MD Core
60 8'0" by 8'0 Std. Pair SVR
2 pt.
No Requires thermal pin door to door
60 6'0" by 9'0" Std. Pair SVR 2pt No Requires thermal pin door to door
60 6'0" by 9'0" Std. Pair CVR 2pt. Yes Requires thermal pin door to door
    60 8'0" by 8'0" Std. Pair SVR/2pt No Requires thermal pin door to door
45 8'0" by 9'0 Double
Egress
CVR/SVR/LBR No Requires 2 thermal pins door to door and LD core
45 8'0" by 9'0 Std.
Pair
CVR/CVC/LBR
 
Yes Requires thermal pin door to door
The product noted above has been tested and qualified per UL 10C, NFPA 252, and CAN/ULC S104 for a 90 Minute Positive Pressure Fire Rating. 

These doors are eligible for use in any "Category C - Standard" frame. These doors may also be installed in frames listed in "Category C - Proprietary" in the accordance with the frame manufacturer's individual listing.

The door noted above is eligible to bear the "S" (for Smoke & Draft Control assemblies) if a listed "Category H - Smoke & Draft Control Gasket" has been applied to the assembly. Please refer to Category H for individual gasket manufacturer's listings.
Listing Report Certificate of Compliance Return to Search
Attributes
Certificate Date of ExpiryDecember 31, 2025
Certificate Date of Initial RegistrationJuly 20, 2021
Certificate NumberWHI21-22066804
CriteriaCAN / ULC S104 (2015) (R2020)
CriteriaUL 10(b) (2008) (R2015)
CriteriaUL 10(c) (2016) Ed. 3 (R:27 May 2021)
CriteriaNFPA 252 (2022)
CSI Code08 14 00 Wood Doors
Fire Resistance20 Min w/Hose Positive Pressure
Fire Resistance45 Min Positive Pressure
Fire Resistance90 Min Positive Pressure
Fire Resistance60 Min Positive Pressure
Listing SectionCATEGORY B - DOORS - ADDITIONAL EDGE-SEALING SYSTEM REQUIRED
Listing SectionCATEGORY A - DOORS - NO ADDITIONAL EDGE-SEALING SYSTEM REQUIRED
Smoke and Draft ControlRating Require a Listed Gasket
Spec ID45357
SwingSingle Swing
SwingStandard Pairs
SwingDouble Egress
SwingTransom
Temperature Rise@ 30 Min = 250° F MAX Where Lites Do Not Exceed 100 IN2