Product Model: MPI KY LLC UL752 Door and Frame Assemblies; Outswing and Inswing
Description UL 752 Ballistic Rating
Rating: Level 1 Level 2 or Level 3
DoorFrame  Material 16 Ga A40 CRS steel with 14 Ga A40 CRS internal steel reinforcement on the door side (adjacent to door for inswing or outside respectively). 14 Ga A40 CRS steel frame with 14 Ga A40 CRS internal reinforcement backing the entire frame.
Door Skin Material 16 Ga A40 CRS steel skins with 14 Ga A40 CRS internal steel reinforcement on threat side only. (Or 14 Ga A40 CRS steel skins with 16 Ga A40 CRS internal steel reinforcement on threat side only.) 16 Ga A40 CRS steel skins with 14 Ga A40 CRS internal steel reinforcement on both sides. (Or 14 Ga A40 CRS steel skins with 16 Ga A40 CRS internal steel reinforcement on both sides.)
Material Option plain(uncoated)/A40/A60/G90 CRS; Type 304 or Type 316 stainless steel
Full length Astragal - Thickness x Width 1/8" x 1.75" 1/4" x 2" [Opt. (2) 1/8" x 2" Wide] 
Single Door - Minimum Size (WxH) 2’-0" W x 2’-0" H
Single Door - Maximum Size (WxH) 4’-0" W x 8’-0" H
Door Pair - Minimum Size (WxH) 4’-0" W x 2’-0" H
Door Pair - Maximum Size (WxH) 8’-0" W x 8’-0" H
Frame  Typ. 2" face-width jamb-stiles and header-rail, single or double rabbet, frame throat 3.5" - 14”, with integral frame stop (min. size 5/8" H x 1" W).  Jamb-stiles & header-rail face-width may range from 2" to 4”.
Frame Weld Continuous weld is applied to both jamb-stile to header-rail miter corner joints, both sides, extending from frame backbend, across frame face, full depth of rabbet, and height of integral door stop.  
Hinges Fire-rated ferrous or non-ferrous hinges must meet the requirements of NFPA 80. Butt hinges per ANSI/BHMA A156.1; Pivots per ANSI/BHMA A156.4; Continuous Hinges per ANSI/BHMA A156.26
Glazing
  • Glazing frames are separate.
  • Metal glazing frame component materials must be same material as the door skin.
  • Separate glazing frames shall be listed with a ballistic rating UL 752 (Level 1,2,3)
  • Glazing (vision panels) shall be listed with a ballistic rating, UL752 (Level 1,2,3). 
  • Glazing must be factory installed.
  • Minimum size for labeled glazing is 12” x 12”, maximum size per the glazing and/or frame listing. 
Max. Door Edge to Frame Gap 1/8" Maximum
Limitations
(Not Listed)
  • Split-leaf, Service Counter, or “Dutch" doors” are not listed.
  • This listing covers the door and door frame only. 
  • Certified door hardware listed separate.
Listing Report Return to Search