Travis Industries - Model 564 GSR2 25K Direct Vent Gas Fireplace Heater Company: Travis Industries, Inc.

Product Vented Gas Fireplace Heater
Brand Name Fireplace Xtrordinair
Description The model 564 GSR2 25K is a direct vented gas fireplace suitable for use with natural gas or propane.  The unit is factory installed for use with natural gas.  A gas appliance conversion kit is provided to convert the fireplace to propane.
The model 564 GSR2 25K features an automatic intermittent/standing pilot ignition system.  A remote control is provided with the appliance to turn the fireplace off and on.
Models 564 GSR2 25K
Model Similarity None
Electrical Ratings 120V, 1.5A, 60Hz, 150W

APPLIANCE RATINGS
  NATURAL GAS PROPANE
Model 564 GSR2 25K
Orifice Size (DMS) #52(F), #51(R) #60(F), #60(R)
Normal Input Rate (Btu/hr) 25,000 25,000
Manifold Pressure at Normal Input Rate (in/wc) 3.5 11
Minimum Input Rate (Btu/hr) 7,500 6,500
Manifold Pressure at Minimum Input Rate (in/wc) 1.6 2.9
Minimum Inlet Pressure (in/wc) 5.5 11

VENTING INFORMATION
VENTING
Vent Type DuraVent Direct-Vent Pro
Vent Size (rear vent) 5”x8”
Vent Size (top vent) 4”x6 5/8”
Max. Vertical Length (rear vent) 40 feet
Min. Vertical Length (rear vent) 10 feet
Max. Vertical Length (top vent) 40 feet
Min. Vertical Length (top vent) 10 feet
Max. Horizontal Length (rear vent) 4 feet
Min. Horizontal Length (rear vent) 4 inches
Max. Horizontal Length (top vent) 4 feet
Min. Horizontal Length (top vent) 4 inches
Max. Horizontal Length at Min. Vertical Length (rear vent) 4 feet horizontal with two 90° elbows
Min. Vertical Length at Max. Horizontal Length (rear vent) 20 feet horizontal with two 90° elbows at 22 feet vertical
Max. Horizontal Length at Min. Vertical Length (top vent) 4 feet horizontal with one 90° elbow
Min. Vertical Length at Max. Horizontal Length (top vent) 20 feet horizontal with one 90° elbow at 21 feet vertical
Max. Number of Elbows 4

CLEARANCES TO COMBUSTIBLE CONSTRUCTION
FIREPLACE CLEARANCES
Adjacent exposed wall (in) 1.0
Enclosure Side (in) 0.5
Enclosure Back (in) 0.5
Floor 0
12” Deep Mantle from floor (in) 38.5
Listing Report Return to Search
Attributes
CriteriaANSI Z21.88 / CSA 2.33 Ed. 7 (2016)
CriteriaCSA 2.17 Ed.4 (2017) (R2022)
CSI Code10 30 00 Fireplaces and Stoves
Fuel TypePropane
Fuel TypeNatural Gas
Listing SectionGAS-FIRED VENTED ROOM HEATERS
Spec ID46619
Design Documents
No Results
Public Documents
No Results