Intertek Directory of Building Products

Next Door Bullet Resistant Commercial Steel Door and Frame (UL 752, Levels 1,2,3) Company: Next Door Company

BULLET RESISTANT DOOR & FRAME ASSEMBLY DESCRIPTIONS

Product Model: Commercial Steel Door and Frame Assemblies; Outswing and Inswing; with optional Vision Lite, Models:
  • B1 (UL752 Level 1);
  • B2 (UL752 Level 2); and
  • B3 (UL752 Level 3).
Description UL 752 Ballistic Rating
Rating: Level 1 Level 2 or Level 3
DoorFrame  Material 16 Ga A60 CRS steel 12 Ga A60 CRS steel frame with 16 Ga A60 CRS internal frame reinforcement lining the frame return, frame face, and depth of rabbet, located adjacent to door.
Door Skin Material 16 Ga A60 CRS steel skins with 14 Ga A60 CRS internal steel reinforcement on the threat side only 12 Ga A60 CRS steel
Material Options plain (uncoated) CRS / A60 / G90; Type 304 or Type 316 stainless steel
Full length Astragal - Thickness x Width 12 Ga x 1.5" W (minimum), same material as door skin 1/4" thk x 2" W, same material as door skin
Single Door - Minimum Size (WxH) 2’-6" W x 6’-8" H
Single Door - Maximum Size (WxH) 4’-0" W x 10’-0" H
Door Pair - Minimum Size (WxH) 4’-0" W x 6’-8" H
Door Pair - Maximum Size (WxH) 8’-0" W x 10’-0" H
Frame  Typ. 2" face-width jamb-stiles and header-rail, single or double rabbet, frame throat 4" - 14” (2.0" Min. Single Rabbet), with integral frame stop (min. size 5/8" H x 1" W).  Jamb-stiles & header-rail face-width may range from 2" to 4”.
Frame Weld Continuous weld is applied to both jamb-stile to header-rail miter corner joints, both sides, extending from frame backbend, across frame face, full depth of rabbet, and height of integral door stop.  
Hinges Fire-rated ferrous or non-ferrous hinges must meet the requirements of NFPA 80. Butt hinges per ANSI/BHMA A156.1; Pivots per ANSI/BHMA A156.4; Continuous Hinges per ANSI/BHMA A156.26
Glazing
  • Glazing frames supplied by others, not integral to frame.
  • Metal Frames for glazing shall be same material as door skin.
  • Metal Frames for glazing shall be listed for UL 752 (Level 1,2, or 3)
  • Glazing (vision panels) shall be listed for UL752 (Level 1,2, or 3). 
  • Glazing must be factory installed.
  • Minimum size for labeled glazing is 12” x 12”, maximum size per the glazing and/or frame listing. 
Max. Door Edge to Frame Gap 1/8" Maximum
Limitations
(Not Listed)
  • Split-leaf, Service Counter, or “Dutch" doors” are not listed.
  • This listing covers the door and door frame only. 
  • Certified door hardware listed separate.
Listing Report Return to Search
Attributes
CriteriaUL 752 (2011)
CSI Code08 10 00 Doors and Frames
CSI Code08 30 00 Specialty Doors and Frames
CSI Code08 11 13 Hollow Metal Doors and Frames
Listing SectionBULLET/FORCED ENTRY RESISTANT PRODUCTS
Spec ID46979