Intertek Directory of Building Products

Carlisle Spray Foam Insulation - SealTite™ Pro Open Cell Company: Carlisle Spray Foam Insulation Code Compliance Research Reports: CCRR-1121

SealTite™ Pro Open Cell is a water blown spray-applied cellular polyurethane foam plastic insulation that is installed on or in interior and exterior walls, floors, ceilings and the underside of roof decks. The foam plastic insulation is a two-component open-cell, one-to-one by volume spray foam system with a nominal density of 0.5 pcf. The insulation is produced in the field by combining a polymeric isocyanate (A component) with a polymeric resin blend (B component). SealTite™ Pro Open Cell is recognized in Intertek CCRR-1121.
 
SealTite™ Pro Open Cell meets the requirements of Mandatory Testing and selected Option Testing of ICC 1100 and ICC-ES AC377 as described in Intertek Code Compliance Research Report CCRR-1121.

MATERIAL RATINGS
Test Standard Test Type Rating / Requirement
ASTM C518 Thermal resistance,
R-value (°F·ft2·h/Btu)
See CCRR-1121
ASTM D1622 Density 0.5 - 1.5 lb/ft3
ASTM D1623 Tensile Strength 3 psi minimum
ASTM D2126 Aged for 168 hrs
@158°F, 97% R.H.
15% maximum change
ASTM D2856 Closed Cell Content < 90%
ASTM E96 (Dessicant Method) Water Vapor Transmission See CCRR-1121
ASTM E283 Air Leakage @ 3.5 in. thickness 0.02 L/s/m2 maximum
NFPA 259 Potential Heat of
Building Materials
See CCRR-1121

FLAME SPREAD RATINGS
Test Standard Thickness Flame Spread
Index
Smoke
 Development
Index
ASTM E84 4 in. maximum 25 or less 450 or less

OTHER FIRE RATINGS
Test Standard Configuration Result
ASTM E119 See CCRR-1121 Met requirements
as configured

ICC 1100, Section 302.5
ICC-ES AC377,
Appendix X
See CCRR-1121 Met requirements
as configured
NFPA 285 See CCRR-1121 Met requirements
as configured
NFPA 286 See CCRR-1121 Met acceptance criteria of IBC Section 803.1.2.1 and IRC Section R302.9.4 as configured
 
CODE COMPLIANCE RESEARCH REPORT
Evaluation Method Building Code CCRR Number
ICC 1100
ICC-ES AC377
2021, 2018, 2015 IBC
2021, 2018, 2015 IRC
2021, 2018, 2015 IECC
CCRR-1121
Listing Report Return to Search
Attributes
CriteriaNFPA 285 (2019)
CriteriaICC-ES AC377 (February 2020)
CriteriaASTM E84 (2018b)
CriteriaASTM E119 (2018b)
CriteriaICC 1100 (2019)
CSI Code07 21 00 Thermal Insulation
CSI Code07 21 19 Foamed-In-Place Insulation
Listing SectionBUILDING MATERIALS WITH SURFACE BURNING CHARACTERISTICS
Spec ID47093
Design Documents
No Results
Code Compliance Research Reports
Public Documents
No Results