Carlisle Spray Foam Insulation - Foamsulate™ 50
Company: Carlisle Spray Foam Insulation
Code Compliance Research Reports: CCRR-0292
Foamsulate™ 50 is a water blown spray-applied cellular polyurethane foam plastic insulation that is installed in on or in interior and exterior walls, floors, ceilings and the underside of roof decks. The foam plastic insulation is a two-component open-cell, one-to-one by volume spray foam system with a nominal density of 0.5 pcf. The insulation is produced in the field by combining a polymeric isocyanate (A component) with a polymeric resin blend (B component). Foamsulate™ 50 is recognized in Intertek CCRR-0292.
MATERIAL RATINGS
Test Standard |
Test Type |
Rating |
ICC 1100
ICC-ES AC377 |
Mandatory Properties |
Meets requirements for Low-Density Insulation Applications |
ASTM E283
(modified per ICC-ES AC377) |
Air Permeability |
<0.02 L/s•m2 |
FLAME SPREAD RATINGS
Test Standard |
Flame Spread |
Smoke Development |
ASTM E84 |
25 or less at nominal
4 inches thickness |
450 or less at nominal
4 inches thickness |
FIRE RATINGS
Test Standard |
Rating |
Design Number |
NFPA 286 |
Meets IBC/IRC acceptance criteria for interior wall and ceiling finishes with selected intumescent coatings |
N/A; See CCRR-0292 |
ICC 1100, Section 302.5
ICC-ES AC377, Appendix X |
Meets acceptance criteria for use in certain attics and crawl spaces without prescriptive ignition barriers with selected intumescent coatings |
N/A; See CCRR-0292 |
ASTM E119 |
1h, non-loadbearing |
1h, non-loadbearing;
See CCRR-0292 |
CODE COMPLIANCE RESEARCH REPORT
Evaluation Method |
Building Code |
CCRR Number |
ICC 1100
ICC-ES AC377 |
2021, 2018 and 2015 International Building Code
2021, 2018 and 2015 International Residential Code
2021, 2018 and 2015 International Energy Conservation Code |
CCRR-0292 |