Jeld-Wen 20 Min Wood Flush Fire Door - Cat A & Cat B
Company: JELD-WEN, Inc.
CATEGORY A DOORS - NO ADDITIONAL EDGE-SEALING SYSTEM REQUIRED:
Wood Core Type (Particle Board Core), Swinging Flush Design Fire Door with Inlay Moulding for installation singly or in pairs in 20 minute locations (without Hose Stream Test) for use in any Category C Standard Frames.
Limitations: Cylindrical and Mortise Latches with 2-3/4" backset/Surface or Mortised Automatic or Manual Top and Bottom Flush Bolts/Surface Mounted Vertical Rod Fire Exit Hardware/Surface Mounted Closer/Automatic Door Bottoms/Vinyl Veneer Covering.
Configuration |
Maximum Size* |
Single |
4'0" wide x 9'0" high |
Pair |
8'0" wide x 9'0" high |
Double Egress |
8'0" X 9'0" |
Mineral Core Type Swinging Flush Design Fire Door with inlay Moulding for installation singly or in pairs in up to 60 minutes. For use in any Category C Standard Frame.
Limitations: Cylindrical with 2-3/4" Backset/Surface Bolts/Surface Mounted Vertical Rod Fire Exit Hardware/Surface Mounted Closer/Automatic Door Bottoms/Viewer/Temperature Rise 250°F at 30 minutes.
Configuration |
Maximum Size* |
Single |
4'0" wide x 8'0" high |
Pair |
8'0" wide x 8'0" high |
Double Egress |
N/A |
*See manufacturer's installation instructions for additional information, restrictions and limitations.
Testing Standard: UBC-7-2-97/UL-10C (Positive Pressure).
Limitations: VingCard Essence Mortise Single Point Lock
Configuration |
Maximum Size* |
Single |
4'0" wide x 8'0" high |
Pair |
N/A |
Double Egress |
N/A |
Rating: |
Core: |
Hardware Series: |
Lockblock requirements: |
Intumescent / Protection Requirements: |
20 Minute Without Hose Stream |
Particle Board |
VingCard Essence |
No lockblock required |
No intumescent requirements within the door. For wood frame applications, a 2 x 16mm strip of listed intumescent is required to be placed within the perimeter of the cut-out for the strike within the frame. |
* Particleboard includes LSL, Stave, Particleboard, Agri Core. Minimum core density 25 pcf.
* Standard mortise hardware does not require intumescent in the mortise pocket.
* Intertek does not certify the hardware or any electrified hardware used in this addendum. Intertek is approving the cutout only.
* All existing edge seal restrictions for the fire doors apply.
* Includes 1-3/4" doors only.
* No Profile core doors.
* Solid core wood doors which have flush construction only. All other multiple component laminated core designs, such as but not limited to multi-component acoustical door designs, are not allowed.
** The maximum size single leaf that the lockset is eligible to be installed within is 4 feet wide by 8 feet high.
Evaluated to the following:
This category includes doors evaluated without an edge-sealing system between the door and frame. It also includes doors evaluated with a sealing system incorporated (concealed or visible) into the edge of the door by the licensed manufacturer or machining distributor.
Meeting edges of pairs may require an astragal or an edge-sealing system. Please refer to individual door listings.
These doors are eligible for use in any "Category C - Standard" frame. These doors may also be installed in frames listed in "Category C - Proprietary" in the accordance with the frame manufacturer's individual listing.
All doors listed in Category A are eligible to bear the "S" (for Smoke & Draft Control assemblies) if a listed "Category H - Smoke & Draft Control Gasket" has been applied to the assembly. Please refer to Category H for individual gasket manufacturer's listings.
All doors in this category are identified by a label or marking bearing the wording, "Listed Fire Door", a time interval, a temperature rise rating, a serial number and the Warnock Hersey Certification Mark and "UBC-7-2-97/UL-10C". See Positive Pressure Section Header for more information.
CATEGORY B - DOORS - ADDITIONAL EDGE-SEALING SYSTEM REQUIRED:
Wood Core Type (Particle Board Core), Swinging Flush Design Fire Door with Inlay Moulding for installation singly or in pairs in 14, 16 gauge labeled steel door frames for 20 minute locations (without Hose Stream Test) using a field applied edge-sealing systems. For use in any "Category C - Standard" frame. These doors may also be installed in frames listed in "Category C - Proprietary" in accordance with the door manufacturer's installation instructions.
Limitations: Cylindrical and Mortise Latches to 2-3/4" Backset/Surface or Mortised Automatic or Manual Top and Bottom Flush Bolts/Surface Mounted Vertical Rod Fire Exit Hardware/Surface Mounted Closer/Automatic Door Bottoms/Vinyl Veneer Covering.
Configuration
|
Maximum Size*
|
Single |
4'0" wide x 9'0" high |
Pairs |
8'0" wide x 9'0" high |
Double Egress |
8'0" X 9'0" |
Wood Core Type (Particle Board Core) Routed Simulated Panel, Swing-Type Fire Door for installation singly or in pairs in up to 20 minute locations. For use in any "Category C - Standard" Frame. These doors may also be installed in frames listed in "Category C - Proprietary" in accordance with the door manufacturer's installation instructions. Field-Applied Edge Seal System is required. Refer to the door manufacturer's installation instructions for Edge-Seal System requirements.
Limitations: Cylindrical and Mortise Latches with Maximum 2-3/4" Backset and Minimum 1/2" Bolt Throw for single swing door and 3/4" Bolt Throw for Pairs/Surface-Mounted Vertical Rod, Rim or Mortise Type Fire Exit Hardware/Automatic or Manual Flush Bolts/Surface Bolts/Surface-Mounted Closer. Door Pairs with Hose Stream require 4-Point Latching. Doors Pairs without Hose Stream may have 3 or 4-Point Latching.
Configuration
|
Maximum Size*
|
Single |
4'0" wide x 9'0" high |
Pair |
8'0" wide x 9'0" high |
Double Egress |
NA |
Medium Density Fiberboard (MDF) Type Routed Simulated Panel or Flat Panel, Swinging-Type Fire Door for installation singly or in pairs in up to 20 minute locations without hose stream. For use in any "Category C - Standard" Frame. These doors may also be installed in frames listed in "Category C - Proprietary" in accordance with the door manufacturer's installation instructions. Field-Applied Edge Seal System is required. Refer to the door manufacturer's installation instructions for Edge-Seal System requirements.
Limitations: Cylindrical and Mortise Latches with Maximum 2-3/4" Backset and Minimum 1/2" Bolt Throw for single swing door and 3/4" Bolt Throw for Pairs/Surface-Mounted Vertical Rod, Rim or Mortise Type Fire Exit Hardware or Manual Flush Bolts/Surface Bolts/Surface-Mounted Closer. Door Pairs require 3-Point Latching.
Configuration
|
Maximum Size*
|
Single |
4'0" wide x 9'0" high |
Pair |
8'0" wide x 9'0" high |
Double Egress |
8'0" X 9'0" |
*See manufacturer's installation instructions for additional information, restrictions and limitations.
Testing Standards: UBC-7-2-97/UL-10C (Positive Pressure).
Evaluated to the following:
This category includes doors evaluated with an edge-sealing system (Category G) field-applied to the labeled frame or door. The application of the edge-sealing system does not require any machining of the frame or door. Please refer to "Category G - Edge-Sealing System" for individual manufacturer's listings.
These assemblies are eligible for use in any "Category C - Standard" frame. These doors may also be installed in frames listed in "Category C - Proprietary" in the accordance with the frame manufacturer's individual listing.
All doors listed in Category B are eligible to bear the "S" (for Smoke & Draft Control assemblies) if a listed "Category H - Smoke & Draft Control Gasket" has been applied to the assembly. Please refer to Category H for individual gasket manufacturer's listings.
All doors in this category are identified by a label or marking bearing the wording, "Listed Fire Door", a time interval, a temperature rise rating, a serial number and the Warnock Hersey Certification Mark and "UBC-7-2-97/UL-10C". See Positive Pressure Section Header for more information