Intertek Directory of Building Products

Jeld-Wen 20 Minute Without Hose Aluminum Door Frame (Knock Down) Company: JELD-WEN, Inc.

20 Minute Without Hose Stream Aluminum Door Frame (Knock-Down) for use in steel stud/wood stud drywall and masonry walls.  Frame may be installed with a sidelite. 
SIZE
  Single Swing Pairs  With Sidelite
Maximum Allowable Width 4’-0” 8’-0” 6’-0”  (4’-0” door with 2’-0” lite)
Maximum Allowable Height 9’-0” 9’-0” 9’-0”
Minimum Stop Depth 0.500” 0.500” 0.500”
Minimum Soffit 0.500” 0.500” 0.500”
Minimum Rabbet 1.667” 1.667 1.667
Minimum Face 1.475” 1.475” 1.475”
Minimum Wall Thickness
(Throat Opening)
3.750” 3.750” 3.750”
 
EVALUATED TO THE FOLLOWING
This category includes frames based on ANSI-A155.1/UL-63 and includes sidelight/transom assemblies. These frames are qualified for use in positive pressure assemblies, with Category A doors, or with Category B doors utilizing Category G edge-sealing systems. These frames, when installed in pairs in drywall construction, shall have anchors installed in the head section, minimum 24" o.c. These listings will not reference specific door types, as all door types are eligible.
All frames in this category are identified by a label or marking bearing the wording, "Listed Fire Door Frame", and the Warnock Hersey Certification Mark. Frames rated at less than 3 hours will have a time interval noted on the label/marking.
Listing Report Return to Search
Attributes
CriteriaUL 10(c) (1998)
CriteriaUBC 7-2 (1997)
CriteriaUL 10(c) (2009)
CSI Code08 11 00 Metal Doors and Frames
CSI Code08 11 16 Aluminum Doors and Frames
Fire Resistance20 Min w/out Hose Positive Pressure
GlazingSide Light/Panel
Listing SectionDOOR FRAMES
Spec ID47552
SwingSingle Swing
SwingStandard Pairs
Design Documents
No Results
Public Documents