Intertek Directory of Building Products

Jeld-Wen 90 Minute Aluminum Door Frame Company: JELD-WEN, Inc.

90 Minute Rated Aluminum Door Frame (Knock-Down) for use in steel stud/wood stud drywall and masonry walls. 
SIZES
 
  Single Swing Pairs 
Maximum Allowable Width 4’-0” 6’-0”
Maximum Allowable Height 9’-0” ** 8’-0”
Minimum Stop
Height
0.500” 0.500”
     
**NOTE: Maximum height of door is not to exceed 8' when door width is over 3'-0" wide.
     
Minimum Wall Thickness
(Throat Opening)
4.875” 4.875”
 
 
Frames Evaluated to the Following:
Unless otherwise noted, assemblies in this section have been tested to the following standards:

CAN/ULC S104, Standard Method for Fire Tests of Door Assemblies;
NFPA-252, Standard Methods of Fire Tests of Door Assemblies;
UL-10B, Standard for Fire Tests of Door Assemblies;
UL-10C, Standard for Positive Pressure Fire Tests of Door Assemblies;
and are installed, unless otherwise noted, in accordance with the following:
NFPA-80, Standard for Fire Doors and Other Opening Protectives;
Manufacturer's Installation Instructions;
All frames are identified by either a label or embossed marking bearing the wording "Fire Door Frame" and the Intertek WH Certification Mark. Frames rated for less than 3 hours also bear the time interval.
Listing Report Return to Search
Attributes
CriteriaCAN / ULC S104 (1980) (R1985)
CriteriaNFPA 252 (2008)
CriteriaUL 10(b) 2008 (R2009)
CriteriaUL 10(c) (2009)
CriteriaNFPA 252 (2012)
CSI Code08 11 16 Aluminum Doors and Frames
Fire Resistance20 Min PP Category C Proprietary Frame
Fire Resistance45 Min PP Category C Proprietary Frame
Fire Resistance90 Min NP Fire Doorframe
Fire Resistance60 Min PP Category C Proprietary Frame
Fire Resistance90 Min PP Category C Proprietary Frame
Fire Resistance90 Minute Fire Rated
Listing SectionCATEGORY C - PROPRIETARY FRAMES
Listing SectionDOOR FRAMES
Spec ID47555
SwingSingle Swing
SwingStandard Pairs
Design Documents
No Results
Public Documents
No Results