Jeld-Wen 90 Minute Aluminum Door Frame
Company: JELD-WEN, Inc.
90 Minute Rated Aluminum Door Frame (Knock-Down) for use in steel stud/wood stud drywall and masonry walls.
SIZES
| |
Single Swing |
Pairs |
| Maximum Allowable Width |
4’-0” |
6’-0” |
| Maximum Allowable Height |
9’-0” ** |
8’-0” |
Minimum Stop
Height |
0.500” |
0.500” |
| |
|
|
| **NOTE: Maximum height of door is not to exceed 8' when door width is over 3'-0" wide. |
| |
|
|
Minimum Wall Thickness
(Throat Opening) |
4.875” |
4.875” |
Frames Evaluated to the Following:
Unless otherwise noted, assemblies in this section have been tested to the following standards:
CAN/ULC S104, Standard Method for Fire Tests of Door Assemblies;
NFPA-252, Standard Methods of Fire Tests of Door Assemblies;
UL-10B, Standard for Fire Tests of Door Assemblies;
UL-10C, Standard for Positive Pressure Fire Tests of Door Assemblies;
and are installed, unless otherwise noted, in accordance with the following:
NFPA-80, Standard for Fire Doors and Other Opening Protectives;
Manufacturer's Installation Instructions;
All frames are identified by either a label or embossed marking bearing the wording "Fire Door Frame" and the Intertek WH Certification Mark. Frames rated for less than 3 hours also bear the time interval.