Intertek Directory of Building Products

Jeld-Wen Infinity/Millenium 20 Min Fire Door w/Inlay Moulding Company: JELD-WEN, Inc.

Category A Door - No Additional Edge Sealing System Required
Wood Core Type (Particle Board Core), Swinging Flush Design Fire Door with Inlay Moulding for installation singly or in pairs in 20 minute locations (without Hose Stream Test) for use in any Category C Standard Frames. 

Limitations: Cylindrical and Mortise Latches with 2-3/4" backset/Surface or Mortised Automatic or Manual Top and Bottom Flush Bolts/Surface Mounted Vertical Rod Fire Exit Hardware/Surface Mounted Closer/Concealed Overhead Closer/Automatic Door Bottoms/Vinyl Veneer Covering.  Door can also be installed in an square top or arched door configuration.
 
Configuration Maximum Size*
Single 4'0" wide x 8'0" high
Pair 8'0" wide x 8'0" high
Double Egress N/A
 
*See manufacturer's installation instructions for additional information, restrictions and limitations.
Testing Standard: UBC-7-2-97/UL-10C (Positive Pressure).
 
 
Evaluated to the following...
This category includes doors evaluated without an edge-sealing system between the door and frame. It also includes doors evaluated with a sealing system incorporated (concealed or visible) into the edge of the door by the licensed manufacturer or machining distributor.
 
Meeting edges of pairs may require an astragal or an edge-sealing system. Please refer to individual door listings.
These doors are eligible for use in any "Category C - Standard" frame. These doors may also be installed in frames listed in "Category C - Proprietary" in the accordance with the frame manufacturer's individual listing.
All doors listed in Category A are eligible to bear the "S" (for Smoke & Draft Control assemblies) if a listed "Category H - Smoke & Draft Control Gasket" has been applied to the assembly. Please refer to Category H for individual gasket manufacturer's listings.
All doors in this category are identified by a label or marking bearing the wording, "Listed Fire Door", a time interval, a temperature rise rating, a serial number and the Warnock Hersey Certification Mark and "UBC-7-2-97/UL 10C".
Category B Door - Additional Edge Sealing System Required
Wood Core Type (Particle Board Core), Swinging Flush Design Fire Door with Inlay Moulding for installation singly or in pairs in 14, 16 gauge labeled steel door frames for 20 minute locations (without Hose Stream Test) using a field applied edge-sealing systems. For use in any "Category C - Standard" frame. These doors may also be installed in frames listed in "Category C - Proprietary" in accordance with the door manufacturer's installation instructions.


Limitations: Cylindrical and Mortise Latches to 2-3/4" Backset/Surface or Mortised Automatic or Manual Top and Bottom Flush Bolts/Surface Mounted Vertical Rod Fire Exit Hardware/Surface Mounted Closer/Automatic Door Bottoms/Vinyl Veneer Covering.  
 
Configuration Maximum Size*
Single 4'0" wide x 8'0" high
Pairs 8'0" wide x 8'0" high
Double Egress NA
 
*See manufacturer's installation instructions for additional information, restrictions and limitations.
Testing Standards: UBC-7-2-97/UL-10C (Positive Pressure).

 
Evaluated to the following...
This category includes doors evaluated with an edge-sealing system (Category G) field-applied to the labeled frame or door. The application of the edge-sealing system does not require any machining of the frame or door. Please refer to "Category G - Edge-Sealing System" for individual manufacturer's listings.
 
These assemblies are eligible for use in any "Category C - Standard" frame. These doors may also be installed in frames listed in "Category C - Proprietary" in the accordance with the frame manufacturer's individual listing.
All doors listed in Category B are eligible to bear the "S" (for Smoke & Draft Control assemblies) if a listed "Category H - Smoke & Draft Control Gasket" has been applied to the assembly. Please refer to Category H for individual gasket manufacturer's listings.
All doors in this category are identified by a label or marking bearing the wording, "Listed Fire Door", a time interval, a temperature rise rating, a serial number and the Warnock Hersey Certification Mark and "UBC-7-2-97/UL 10C".
Listing Report Return to Search
Attributes
CriteriaUBC 7-2 (1997)
CriteriaUL 10(c) (2009)
CriteriaNFPA 252 (2012)
CriteriaUL 10(c) (2016)
CSI Code08 10 00 Doors and Frames
CSI Code08 14 00 Wood Doors
Fire Resistance20 Min w/out Hose Stream PP Cat A Door
Fire Resistance20 Min w/out Hose Stream PP Cat B Door
Listing SectionCATEGORY B - DOORS - ADDITIONAL EDGE-SEALING SYSTEM REQUIRED
Listing SectionCATEGORY A - DOORS - NO ADDITIONAL EDGE-SEALING SYSTEM REQUIRED
Spec ID47560
SwingSingle Swing
SwingStandard Pairs
Design Documents
No Results
Public Documents
No Results