Pre-Insulated Metal AWIP Wall and Roof Panels Company: All Weather Insulated Panels

AWIP Wall and Roof Panels are insulated metal panels with various profiles. The following AWIP panel profiles are covered in this Listing Report:

Panels for use in wall applications:
PRODUCT INSULATION MATERIAL FACING MATERIAL DIMENSIONS
HE40 Proprietary
medium density
foam plastic
26, 24 or 22 GA Grade 33 steel
ASTM A653 G90 galvanized,
or ASTM A792 AZ50 galvalume steel,
or Stainless Steel 304 (2B Finish)
Panel width: 36”, 40”, or 44"
Panel length: 8’ to 60’
Panel thickness: 2”, 2.5”, 3”, 4”, 5", 6”, and 8"
HE36
HE40A
HE36A
MV40
ST40
ST36
DM40
DM36
FL40
FL36
FW40
DM44
IP40
IP44
DM40-F+ Panel width: 40”
Panel length: 8’ to 60’
Panel thickness: 8”
CW36 Panel width: 36”
Panel length: 8’ to 60’
Panel thickness: 2.5” and  4”
HR3-W Panel width: 40”
Panel length: 8’ to 50’
Panel thickness: 1.5”, 2.5”, 3", 4”, 5” and 6”
HR5-W

Panels for use in roof applications:
PRODUCT INSULATION MATERIAL FACING
MATERIAL
DIMENSIONS
HR3 Proprietary
medium density
foam plastic
26, 24 or 22 GA Grade 33 steel
ASTM A653 G90 galvanized,
or ASTM A792 AZ50 galvalume steel,
or Stainless Steel 304 (2B Finish)
Panel width: 40”
Panel length: 8’ to 50’
Panel thickness: 1.5”, 2.5”, 3", 4”, 5” and 6”
HR5
SR2 Panel width:  40”
Panel length: 8’ to 60’
Panel thickness: 3.25”, 4”, 5” and 6”
RD1 Panel width: 36" or 40”
Panel length: 8’ to 60’
Panel thickness: 2”, 2.5”, 3”, 4”, 5”, and 6”
RD1-M Panel width: 36" or 40”
Panel length: 8’ to 60’
Panel thickness: 2”, 2.5”, 3”, 4”, 5”, and 6”

RATINGS

Surface Burning Characteristics
Test Standard Rating Design Number
ASTM E841 Flame Spread Index ≤ 25
Smoke Developed Index ≤ 450
NA
CAN/ULC S102 Flame Spread Index: 0
Smoke Developed Index: 5
NA
ASTM E2768-11 (R2018)
 
Flame Spread Index: 10
Smoke Developed Index: 180
NA
Panels were tested with metal skin removed and core exposed to fire.

Wall Panels (All Ratings apply to maximum panel thickness)
Test Standard Rating Design Number
CAN/ULC S138 Meets Requirements when installed with both AWIP Wall and Roof Panels
(unsprinklered room configuration)
NA
CAN/ULC S101* 15 minute-stay-in-place AWIP/FWPA 15-01
ASTM E119 and CAN/ULC S101* 1 hour AWIP/FWPA 60-03
NFPA 286 Meets Requirements when installed with both AWIP Wall and Roof Panels NA
2-8 in. thick DM40, HE40, HE40A, MV40, ST40, FL40, FW40, RD1, RD1-M and DM 44
No joint treatment 
NA
2.5-4 in. thick CW36, HR5-W, and HR3-W
Butyl tape applied to joints
NFPA 285 (All AWIP Wall Panels except CW36, HR3-W & HR5-W) Meets Requirements AWIP/FWPA 30-01
NFPA 285 (CW36, HR5-W, and HR3-W Wall Panels) Meets Requirements  AWIP/FWPA 30-02
NFPA 268 Meets Requirements NA
CAN/ULC S134 Installed vertically and horizontally Meets Requirements AWIP-FWPA 25-01 (Vertical Installation)
AWIP-FWPA 25-02 (Horizontal Installation)
* Stainless Steel skins are not approved for use on fire-resistance (ASTM E119 or CAN/ULC S101) rated assemblies.

Roof Panels (All Ratings apply to maximum panel thickness)
Test Standard Rating Design Number
CAN/ULC S126 Flame Spread at 10 minutes: 0
Flame Spread at 30 minutes: 0
NA

ASTM E108 and CAN/ULC S107 Class A Assemblies
Assembly No. 
1
Slope: 
Unlimited
Deck:  Minimum nominal 3/8 in. thick Code Compliant exterior grade plywood (or) Code Compliant non-combustible sheathing
Details:  2.5”-6” thick HR5, HR3, or SR2 panel installed in accordance with manufacturer’s installation instructions.
Assembly No.  2
Slope:  Unlimited
 Deck:  No solid sheathing – Code Compliant metal and timber purlins
Details: 
4”-6” thick HR5, HR3, or SR2 panel installed in accordance with manufacturer’s installation instructions.
Assembly No.  3
 Slope:  Unlimited
Deck:  Minimum nominal 3/8 in. thick Code Compliant exterior grade plywood (or) Code Compliant non-combustible sheathing
Details: 
2.5”-8” thick RD1, or RD1-M panel installed in accordance with manufacturer’s installation instructions.
Assembly No. 
4
Slope:  Unlimited
Deck:  No solid sheathing – Code Compliant metal and timber purlins
Details: 
3”-8” thick RD1, or RD1-M panel installed in accordance with manufacturer’s installation instructions.
Listing Report Return to Search
Attributes
CriteriaCAN / ULC S138 (2006)
CriteriaCAN / ULC S101 (2014)
CriteriaASTM E2768-11 (R2018)
CriteriaCAN / ULC S134 (2013) (R2018)
CriteriaCAN / ULC S102 (2018)
CriteriaASTM E119 (2020)
CriteriaNFPA 286 (2024)
CriteriaNFPA 285 (2024) Ed.2025
CriteriaASTM E108 (2025)
CriteriaASTM E119 (2026)
CriteriaCAN / ULC S126 (2014) Ed.3
CriteriaASTM E84 (2026)
CriteriaASTM E84 (2021a)
CriteriaNFPA 285 (2023)
CriteriaASTM E108 (2020a)
CriteriaNFPA 268 (2021) Ed.2022
CriteriaCAN / ULC S107 (2019)
CriteriaASTM E119 (2024)
CSI Code07 42 63 Fabricated Wall Panel Assemblies
Listing SectionTHERMAL INSULATION BOARDS