AWIP Wall and Roof Panels are insulated metal panels with various profiles. The following AWIP panel profiles are covered in this Listing Report:
Panels for use in wall applications:
| PRODUCT |
INSULATION MATERIAL |
FACING MATERIAL |
DIMENSIONS |
| HE40 |
Proprietary
medium density
foam plastic |
26, 24 or 22 GA Grade 33 steel
ASTM A653 G90 galvanized,
or ASTM A792 AZ50 galvalume steel,
or Stainless Steel 304 (2B Finish) |
Panel width: 36”, 40”, or 44"
Panel length: 8’ to 60’
Panel thickness: 2”, 2.5”, 3”, 4”, 5", 6”, and 8" |
| HE36 |
| HE40A |
| HE36A |
| MV40 |
| ST40 |
| ST36 |
| DM40 |
| DM36 |
| FL40 |
| FL36 |
| FW40 |
| DM44 |
| IP40 |
| IP44 |
| DM40-F+ |
Panel width: 40”
Panel length: 8’ to 60’
Panel thickness: 8” |
| CW36 |
Panel width: 36”
Panel length: 8’ to 60’
Panel thickness: 2.5” and 4” |
| HR3-W |
Panel width: 40”
Panel length: 8’ to 50’
Panel thickness: 1.5”, 2.5”, 3", 4”, 5” and 6” |
| HR5-W |
Panels for use in roof applications:
| PRODUCT |
INSULATION MATERIAL |
FACING
MATERIAL |
DIMENSIONS |
| HR3 |
Proprietary
medium density
foam plastic |
26, 24 or 22 GA Grade 33 steel
ASTM A653 G90 galvanized,
or ASTM A792 AZ50 galvalume steel,
or Stainless Steel 304 (2B Finish) |
Panel width: 40”
Panel length: 8’ to 50’
Panel thickness: 1.5”, 2.5”, 3", 4”, 5” and 6” |
| HR5 |
| SR2 |
Panel width: 40”
Panel length: 8’ to 60’
Panel thickness: 3.25”, 4”, 5” and 6” |
| RD1 |
Panel width: 36" or 40”
Panel length: 8’ to 60’
Panel thickness: 2”, 2.5”, 3”, 4”, 5”, and 6” |
| RD1-M |
Panel width: 36" or 40”
Panel length: 8’ to 60’
Panel thickness: 2”, 2.5”, 3”, 4”, 5”, and 6” |
RATINGS
Surface Burning Characteristics
| Test Standard |
Rating |
Design Number |
| ASTM E841 |
Flame Spread Index ≤ 25
Smoke Developed Index ≤ 450 |
NA |
| CAN/ULC S102 |
Flame Spread Index: 0
Smoke Developed Index: 5 |
NA |
ASTM E2768-11 (R2018)
|
Flame Spread Index: 10
Smoke Developed Index: 180 |
NA |
1 Panels were tested with metal skin removed and core exposed to fire.
Wall Panels (All Ratings apply to maximum panel thickness)
| Test Standard |
Rating |
Design Number |
| CAN/ULC S138 |
Meets Requirements when installed with both AWIP Wall and Roof Panels
(unsprinklered room configuration) |
NA |
| CAN/ULC S101* |
15 minute-stay-in-place |
AWIP/FWPA 15-01 |
| ASTM E119 and CAN/ULC S101* |
1 hour |
AWIP/FWPA 60-03 |
| NFPA 286 |
Meets Requirements when installed with both AWIP Wall and Roof Panels |
NA
2-8 in. thick DM40, HE40, HE40A, MV40, ST40, FL40, FW40, RD1, RD1-M and DM 44
No joint treatment |
NA
2.5-4 in. thick CW36, HR5-W, and HR3-W
Butyl tape applied to joints |
| NFPA 285 (All AWIP Wall Panels except CW36, HR3-W & HR5-W) |
Meets Requirements |
AWIP/FWPA 30-01 |
| NFPA 285 (CW36, HR5-W, and HR3-W Wall Panels) |
Meets Requirements |
AWIP/FWPA 30-02 |
| NFPA 268 |
Meets Requirements |
NA |
| CAN/ULC S134 Installed vertically and horizontally |
Meets Requirements |
AWIP-FWPA 25-01 (Vertical Installation)
AWIP-FWPA 25-02 (Horizontal Installation) |
* Stainless Steel skins are not approved for use on fire-resistance (ASTM E119 or CAN/ULC S101) rated assemblies.
Roof Panels (All Ratings apply to maximum panel thickness)
| Test Standard |
Rating |
Design Number |
| CAN/ULC S126 |
Flame Spread at 10 minutes: 0
Flame Spread at 30 minutes: 0 |
NA |
ASTM E108 and CAN/ULC S107 Class A Assemblies
| Assembly No. |
1
|
| Slope: |
Unlimited
|
| Deck: |
Minimum nominal 3/8 in. thick Code Compliant exterior grade plywood (or) Code Compliant non-combustible sheathing |
| Details: |
2.5”-6” thick HR5, HR3, or SR2 panel installed in accordance with manufacturer’s installation instructions. |
| Assembly No. |
2 |
| Slope: |
Unlimited |
| Deck: |
No solid sheathing – Code Compliant metal and timber purlins |
| Details: |
4”-6” thick HR5, HR3, or SR2 panel installed in accordance with manufacturer’s installation instructions.
|
| Assembly No. |
3 |
| Slope: |
Unlimited |
| Deck: |
Minimum nominal 3/8 in. thick Code Compliant exterior grade plywood (or) Code Compliant non-combustible sheathing |
| Details: |
2.5”-8” thick RD1, or RD1-M panel installed in accordance with manufacturer’s installation instructions.
|
| Assembly No. |
4
|
| Slope: |
Unlimited |
| Deck: |
No solid sheathing – Code Compliant metal and timber purlins |
| Details: |
3”-8” thick RD1, or RD1-M panel installed in accordance with manufacturer’s installation instructions.
|