Intertek Directory of Building Products

Jotul Model F602 V3 Solid Fuel Room Heater Company: Jøtul North America, Inc.

Product Solid Fuel Room Heater
Brand Name Jotul
Description Cast iron freestanding stove with overall dimensions of 13-in wide x 20-in deep x 25-in high.  The flue is connected either at the top rear of the stove or the upper back of the stove with a 4.5-in cast iron flue collar with a 6-in adapter.  The fuel door includes a glass viewing area at the top with an air wash and an adjustable primary air damper at the bottom of the door.  Secondary air enters at the rear of the stove.

A stainless-steel catalyst is located above the baffle and positioned before the flue collar.
Models F602 V3
Model Similarity None
Ratings None

CLEARANCES TO COMBUSTIBLE CONSTRUCTION
CLEARANCES
  Unprotected Surfaces Protected Surfaces
Side Rear Corner Side Rear Corner
Single wall conn. w/o rear heatshield 21-in
535 mm
13.5-in
345 mm
13-in
330 mm
13-in
330 mm
11-in
280 mm
9-in
230 mm
Single wall conn. w/ rear heatshield 21-in
535 mm
11-in
280 mm
11-in
280 mm
13-in
330 mm
11-in
280 mm
9-in
230 mm
Shielded single wall conn. w/ rear heatshield 21-in
535 mm
9-in
230 mm
9-in
230 mm
13-in
330 mm
8-in
205 mm
8-in
205 mm
Double wall conn. w/ rear heatshield 24-in
610 mm
9-in
230 mm
9-in
230 mm
13-in
330 mm
8-in
205 mm
8-in
205 mm
Double wall conn. w/o rear heatshield 24-in
610 mm
15-in
380 mm
15-in
380 mm
12-in
305 mm
8-in
205 mm
8-in
205 mm
 
VENTING SYSTEM CLEARANCES
  Unprotected surface – vertical installation Protected surface – vertical installation
Single Wall Chimney Connector 18-in
460 mm
6-in
150 mm
Double Wall Chimney Connector Manufacturer listing Manufacturer listing
  Unprotected surface – horizontal installation Protected surface – horizontal installation
Single Wall Chimney Connector 18-in
460 mm
9-in
230 mm
Double Wall Chimney Connector Manufacturer listing Manufacturer listing
 
MINIMUM ALCOVE DIMENSIONS
  Unprotected surface – vertical installation Protected surface – vertical installation
Minimum Width 55-in/1400 mm 41-in/1040 mm
Maximum Depth 48-in/1220 mm 48-in/1220 mm
Height Above Top of Stove 71-in/1805 mm 71-in/1805 mm

FLOOR PROTECTION REQUIREMENTS
Unit is acceptable for use on a combustible surface. A non-combustible protective cover must be placed a minimum of 16-inches (US) or 450 mm (CAN) from the front and 8-inches beyond both sides for the fueling door. Floor protection must extend 2-inches beyond each side of a horizontal chimney connector.
Listing Report Return to Search
Attributes
CriteriaUL 1482:2011 Ed.7 (R2022)
CriteriaCAN / ULC S627 (2023)
CriteriaCAN / ULC 628 (2022) Ed. 4
CSI Code10 30 00 Fireplaces and Stoves
Fuel TypeSolid Fuel - Wood
Listing SectionSOLID FUEL TYPE ROOM HEATERS
Spec ID47997