Intertek Directory of Building Products

SAFTI FIRST SuperClear 45 HS/HS LI Fire Rated Glazing (Doors) Company: SAFTI FIRST

SAFTI FIRST SuperClear 45 HS/HS LI Glazing: For use in fire rated steel and wood doors with rated steel glazing kits up to and including 45 Minutes.

Allowances:
1) Patterns, Opaque, Tints may be applied to one side of the glazing by:
  • Applying a maximum 8 mil (0.008") thick film
  • Sandblasting/acid etching the surface

2) 1/8" high x 1-1/2" wide x 3" long Calcium Silicate or Hardwood setting blocks must be used at quarter points under the bottom edge; and 1/8" thick x 3/4" wide, closed cell foam glazing tape is required on all edges (on both faces) or listed fire-rated glazing tape is required around the perimeter of the glazing on both sides of the glazing such that it is approved for fire-rated durations equal to or greater than the respective glazing product it is used with.

Maximum Visible Width: 33"

Maximum Visible Height: 99-5/8"

Maximum Visible Area: 3,287.6 in2

Minimum Bite: 11/16"

Minimum Thickness: 3/4"

*Listed & Labeled lite kits must be used.

Glazing Markings:  D-H-OH-45
 
*Component Bearing the ETL Certification Mark
 
Limitations: 
 
Listed fire-rated glazing tape is required around the perimeter of the glazing on both sides of the glazing for use with SuperClear 45 HS or SuperClear 45 HS LI Glazing such that it is approved for fire-rated durations equal to or greater than the respective  Glazing product it is used with.  1/8" thick x 3/4" wide setting block required at bottom of glazing between the glazing material and vision kit.

Unless otherwise noted, the glazing has been evaluated for conformance to the following standards listed below:

CAN/ULC S104, Standard Method for Fire Tests of Door Assemblies

NFPA 252, Standard Methods of Fire Tests of Door Assemblies
UL 10C, Positive Pressure Fire Tests of Door Assemblies


Listed products are intended to be installed, unless otherwise noted, in accordance with the following:
 
NFPA 80, Fire Doors & Windows
 
NOTE:  In regard to the SuperClear 45 HS/HS LI Glazing Unit, this listing is in regard to fire resistance only. 

Manufacturer's Instructions
 
Listed maximum sizes of glazing are based on sizes tested and may exceed those allowed by local codes.  Dependent on the end use installation, local codes may require that additional criteria be met to address considerations such as radiant heat hazards and impact safety. Under such circumstances, the prior approval of the Authority Having Jurisdiction must be obtained unless conformance to relevant additional requirements is indicated within the individual listing.
 
Clearance between the edges if the glazing and the inside edge of the frame shall not exceed 1/8" unless otherwise noted in the individual listing or the manufacturer's installation instructions. All glazing is identified by an etched mark or label bearing the ETL Certification Mark.



 
Listing Report Certificate of Compliance Return to Search
Attributes
Certificate Date of ExpiryDecember 31, 2026
Certificate Date of Initial RegistrationMarch 28, 2024
Certificate NumberWHI24 - 20840002
CriteriaCAN / ULC S104 (2015) (R2020)
CriteriaUL 10(c) (2016)
CriteriaUL 10(b) (2008) (R2015)
CriteriaNFPA 252 (2017)
CSI Code08 11 00 Metal Doors and Frames
Fire Resistance45 Min Positive Pressure
Listing SectionCATEGORY D - DOOR/FRAME ASSEMBLIES
Spec ID48346
Design Documents
No Results
Public Documents
No Results