Products Covered:
A.W. Farrell & Son, Inc. Metal Roof Edge Systems
This specification recognizes metal roof edge systems for use with low slope roofing, including metal roof edge systems that are independently terminated and that have been tested for wind resistance.
The tables below provide general system configurations and tested wind resistance values per the referenced test standards. Table foot notes provide additional system material and fastening requirements.
The Intertek Certification Mark applied to each metal edge flashing shows the product has been fabricated by a qualified manufacturer who is authorized to apply the Intertek Certification Mark and who is subject to Intertek periodic follow-up inspections of the manufacturing facility.
| A.W. FARRELL & SON FASCIA FLASHINGS |
Test Standard
ANSI/SPRI/
FM 4435 ES-1 |
Test Method
RE-2 |
Assembly Details
Materials |
Tested2
Resistance
(PSF) |
| Design |
Max. Face
Dimension (in.) |
Flashing |
Cleat1 |
| 8-inch Snap-On Fascia |
8 |
0.05” AL |
22 Gauge |
250 |
| 8-Inch Snap-On Gravel Stop |
8 |
0.05” AL |
22 Gauge |
200 |
AL = Aluminum, 22 gauge material is galvanized steel
1 Cleats are fastened to solid wood substrate dimensional wood nailer with
1-1/2 inch ring shank nails 6 inches on center in two rows. See manufacturer's installation instructions for critical fastener locations and additional installation instructions.