SAFTI FIRST Glazed Framing System with SuperClear 45-HS Company: SAFTI FIRST

Glassprotex (GPX) with SuperClear 45-HS Framing Systems
Assembly Rating - Up To 45 minutes; Non-Bearing framing system.  Non-temperature rise assembly.

The creation of an IGU using metal spacers is allowed. 
  
SuperClear 45-HS - 45 Minute Assembly
Maximum Allowable Clear View Area 3,879 in2
Maximum Allowable Clear View Width 96" 
Maximum Allowable Clear View Height 96" 
Minimum Stop Depth 5/8"
     
Glazing Markings: D-H-OH-45
 
*Component Bearing the Warnock Hersey Certification Mark
 
Note: For applications of these glazing products in door assemblies and window assemblies as well as door vision panel kits, please see listing in appropriate sections.
 
Note: Listed fire-rated open cell glazing tape is allowed for use with SuperClear 45-HS Glazing such that it is approved for fire-rated durations equal to or greater than the respective SuperClear 45-HS Glazing product it is used with.
 
Note: Glazing products used in the designs specified in this Listing are non-directional.
 
Evaluated to the following... 
Design listings are based on, and supported by, proprietary test reports. The test reports further define proprietary design details which make these listings applicable only to the specified products manufactured by the listed manufacture.
 
Unless otherwise noted, the assemblies in this section have been evaluated for conformance to the following standards:
 
CAN/ULC-S106, Standard Method for Fire Test of Window and Glass Block.
NFPA-257, Fire Tests of Window Assemblies.
UL 9, Fire Tests of Window Assemblies
 
Designs listed are minimum construction requirements to achieve fire rating.
 
Unless otherwise noted, fire ratings apply to tests conducted on both sides.
Listing Report Certificate of Compliance Return to Search
Attributes
Certificate Date of ExpiryDecember 31, 2025
Certificate Date of Initial RegistrationMarch 28, 2024
Certificate NumberWHI24 - 20840003
CriteriaNFPA 257 (2012)
CriteriaCAN / ULC S106 (2015) Ed.3
CriteriaUL 9 Ed. 8 (2015)
CSI Code08 41 00 Entrances and Storefronts
Fire Resistance45 Min Positive Pressure
Listing SectionWALL ASSEMBLIES
Spec ID48962