Intertek Directory of Building Products

Koppers Performance Chemicals - FlamePRO Company: Koppers Performance Chemicals Inc.

FlamePRO Fire Retardant Treated Wood is lumber, timber and plywood pressure-treated with FlamePRO water-based fire retardant for interior applications. Plywood ranging from 15/32 to 1-1/8 inches, lumber from 2 x 4 to 2 x 16 inches, and timber from 4 x 4 to 12 x 12 inches is recognized for the species noted below. Plywood is provided in C-D Exposure 1 and higher grades, and lumber as #2 and higher grades.
 
FLAME SPREAD RATINGS
Lumber/Timber: SPF, Southern Yellow Pine, Douglas Fir
Test Standard Flame Spread Smoke Development
ASTM E84      <25      <450
 
Test Standard Maximum Flame Front
ASTM E2768/Extended E84      <10.5 ft.
 
 
Plywood: Southern Yellow Pine, Douglas Fir, Elliotti Pine
Test Standard Flame Spread Smoke Development
ASTM E84      <25      <450
 
Test Standard Maximum Flame Front
ASTM E2768/Extended E84     < 10.5 ft.
 

FIRE RATINGS
Test Standard Rating Design Number
ASTM E119, UL 263 1 hour KPC/FRWT 60-01
ASTM E119, UL 263 1 hour from interior KPC/FRWT 60-02
ASTM E119, UL 263 2 hour from interior KPC/FRWT 120-01
ASTM E119, UL 263 2 hour from interior,
1 hour from exterior
KPC/FRWT 120-02
 
ASTM E119, UL 263 2 hour KPC/FRWT 120-03
 
 
Listing Report Return to Search
Attributes
CriteriaASTM E2768-11 (R2018)
CriteriaASTM E84 (2016)
CriteriaASTM E119 (2018a)
CriteriaUL 263: 2011 Ed. 14 (R2015)
CriteriaASTM E119 (2019)
CSI Code06 05 73 Wood Treatment
CSI Code06 05 73.13 Fire-Retardant Wood Treatment
Listing SectionBUILDING MATERIALS WITH SURFACE BURNING CHARACTERISTICS
Spec ID51339
Design Documents
Public Documents
No Results