Intertek Directory of Building Products

Stronghold Insulation Systems - Insulated Concrete Form (ICF) Systems Company: Stronghold Insulation Systems, Inc. Code Compliance Research Reports: CCRR-0353

The Stronghold ICF System is manufactured using expandable polystyrene (EPS) panels with polypropylene cross-ties. The FX Series are with fixed internal cross-ties; the KD Series are with a reversible, interlocking connection design. The core thicknesses are 4, 6, 8, 10 and 12 inches. The product is available in the following sizes and configurations. 

Stronghold FX Series
  • 4, 6, 8, 10, 12-inch Straight
  • 4, 6, 8, 10, 12-inch 90º Corner
  • 4, 6, 8, 10, 12-inch 45º Corner
Stronghold KD Series
  • 4, 6, 8, 10, 12-inch Straight
  • 4, 6, 8, 10, 12-inch 90º Corner
  • 4, 6, 8, 10, 12-inch 45º Corner
MATERIAL RATINGS
 
Test Standard Test Type Rating
ASTM C578 Physical Properties Met Type II Requirements
ASTM E2634 Physical Properties Met Conditions of Acceptance
CAN/ULC-S701 Physical Properties Met Type 2 Requirements
CAN/ULC-S717.1 Physical Properties Met Conditions of Acceptance

CODE COMPLIANCE RESEARCH REPORT
Evaluation Method Building Code CCRR Number
ICC-ES AC353 2021, 2018 and 2015 International Building Code
2021, 2018 and 2015 International Residential Code
2015 National Building Code of Canada
CCRR-0353

FIRE RATINGS
Test Standard Rating Design Number
ASTM E119
CAN/ULC-S101
3 h STR/ICF 180-01
 
Test Standard Test Specimen Rating
NFPA 286 EPS Panel Thickness: 2-3/4 in.
EPS Density: 1.45 pcf
Interior Finish: 1/2 inch regular gypsum board
Met Conditions of Acceptance

FLAME SPREAD RATINGS

UL723 SURFACE BURNING CHARACTERISICS ON EPS (CEILING VALUES REPORTED)
Material Flame Spread Index Smoke Developed Index
Type II EPS
EPS Nominal Density: 1.5 pcf
≤0 ≤5

UL723 SURFACE BURNING CHARACTERISICS ON EPS
Material Flame Spread Index Smoke Developed Index
Type II EPS
EPS Nominal Density: 1.5 pcf
≤25 ≤450

CAN/ULC S102.2 SURFACE BURNING CHARACTERISICS ON EPS
Material Flame Spread Index Smoke Developed Index
Type II EPS
EPS Nominal Density: 1.5 pcf
<500 >500

This product is under the following quality assurance program:
Product Product Approval No.
Stronghold Insulated Concrete Form (ICF) Systems FL 30543
Listing Report Return to Search
Attributes
CriteriaCAN / ULC S701 (2011)
CriteriaCAN / ULC S102.2 (2010)
CriteriaCAN / ULC S101 (2014)
CriteriaUL 723 (2008) Ed:10 rev. 2010
CriteriaASTM E2634 (2011, R2015)
CriteriaASTM C578 (2015)
CriteriaCAN/ULC-S717.1 (2017)
CriteriaNFPA 286 (2019)
CriteriaICC-ES AC353 (2015)
CriteriaASTM E119 (2018c)
CSI Code03 11 19 Insulating Concrete Forming
Listing SectionCONCRETE FORMS
Spec ID51355
Design Documents
Code Compliance Research Reports
Public Documents
No Results