NCFI InsulStar®Light 12-008, InsulStar®Light Optimaxx 12-008 and InsulStar®Light 12-177109 are two-component, one-to-one by volume, open-cell, spray-applied polyurethane foam insulation systems having a nominal density of 0.5 pcf.
NCFI InsulStar®Light 12-075 is a two-component, low-density, open-cell, spray-applied polyurethane foam insulation having a nominal density of 0.75 pcf.
MATERIAL RATINGS
| Test Standard |
Test Type |
Rating |
| ICC-ES AC377 |
Mandatory Properties |
Low-density Applications |
| ASTM E96 |
Moisture Vapor Transmission |
28.1 perm-inch |
| ASTM E970 (12-008 only) |
Critical Radiant Flux |
> 0.12 W/cm2 |
| ASTM E2178 |
Air Permeability |
< 0.02 L/s·m2 at 4 inches |
| NFPA 259 |
Potential Heat |
12,148 Btu/lb |
FLAME SPREAD RATINGS
| Test Standard |
Flame Spread |
Smoke Development |
| ASTM E84 |
≤ 25 |
≤ 450 |
FIRE RATINGS
| Test Standard |
Rating |
Design Number |
| ICC-ES AC377, Appendix X |
Pass |
See CCRR-0323 |
| NFPA 285 (2019) |
Pass |
See CCRR-0323 |
| NFPA 286 |
Meets requirements of IBC Section 803.1.1 and IRC Section R302.9.4 |
See CCRR-0323 |
CODE COMPLIANCE RESEARCH REPORT
| Evaluation Method |
Building Code |
CCRR Number |
| ICC-ES AC377 |
2021, 2018 and 2015 IBC
2021, 2018 and 2015 IRC
2021, 2018 and 2015 IECC |
CCRR-0323 |