Intertek Directory of Building Products

Tesla Solarglass Roof Company: Tesla Inc. Code Compliance Research Reports: CCRR-0351

Tesla Solarglass Roof is a BIPV roof covering.

This listing applies to the Solarglass Roof BIPV module/tiles, model Nos. SR60T-1, SR72T-1 and SR72T-2,  and the non-energy producing Solarglass Roof Tile models, SRNFT 1, SRNFT 1/6, SRNFT 1/3, SRNFT 1/2, SRNFT 2/3, and SRNFT 5/6 

The Tesla Solarglass BIPV Tiles and non-energy producing Solarglass Roof Tiles are supported and attached by snap engagement to plastic mounting components that are mechanically fastened to prepared roofing. The mounting components are fastened to roof with two 1-1/2 in. ring shank roofing nails with 3/8-in. heads and 1/8-in. shanks.  

Assemblies are intended for use in steep slope roof applications with roof slope equal to or greater than 2:12, installed over minimum 15/32-in. thick code-complying plywood roof decks covered with one layer of underlayment. 

WIND RESISTANCE
Test Standard Rating Assembly Details  
 ASTM D3161-19 CLASS F Rating 
  
1. Deck:  15/32 in. plywood

2. One layer of Tesla Solar Roof Self-Adhered Roofing Underlayment  (model SR-SAUL-1 or SR-SAUL-2)

3. Tesla SolarGlass Roof System (with SR60T-1, SR72T-1, SR72T-2 or SRNFT models)

Eave and rake flashing conditions and attachment per Tesla Installation instructions. 

WIND DRIVEN RAIN
Test Standard Rating Assembly Details & Rating
TAS 100-95

Wind and Wind Driven Rain
 
PASS - No leakage  1. Deck:  15/32 in. plywood

2. One layer of Tesla Solar Roof Self-Adhered Roofing Underlayment (Model SR-SAUL-1 or SR-SAUL-2)

3. Tesla SolarGlass Roof System (with SR60T-1, SR72T-1, SR72T-2, or SRNFT models)

Eave, Valley, and rake flashing conditions and attachment per Tesla installation instructions.

ROOF FIRE CLASSIFICATION: CLASS A - UL 790
Assembly No.  E108-RFU-52115-01   
Slope: Qualifies for use with roof slopes ≥ 2:12 
Deck Type: Combustible Deck 15/32 in. plywood
Details:
 
1.  One layer of Tesla Solar Roof Self-Adhered Roofing Underlayment (Model SR-SAUL-1) 

2.Tesla Solarglass Roof System (with SR60T-1, SR72T-1, SR72T-2, or SRNFT models) 

Attachment and installation per Tesla Installation instructions. 

ROOF FIRE CLASSIFICATION: CLASS C - UL 790
Assembly No.  E108-RFU-52115-02   
Slope: Qualifies for use with roof slopes ≥ 2:12 
Deck Type: Combustible Deck 15/32 in. plywood
Details:
 
1.  One layer of Tesla Solar Roof Self-Adhered Roofing Underlayment (Model SR-SAUL-2) 

2.Tesla Solarglass Roof System (with SR60T-1, SR72T-1, SR72T-2, or SRNFT models) 

Attachment and installation per Tesla Installation instructions. 

Note: the component materials of each system must be applied in the order in which they are listed above. 

ROOF IMPACT RESISTANCE
Test Standard Rating Assembly Details & Rating
FM 4473-11    

 
 
 CLASS 3 1. Deck:  15/32 in. plywood
2. Underlayments as approved for roof fire classification
3. Tesla SolarGlass Roof System (with SR60T-1, SR72T-1, SR72T-2, or SRNFT models) 


CODE COMPLIANCE
Evaluation Method Building Codes Report No.
Code referenced standards 2024, 2021, 2018 IBC
2024, 2021, 2018 IRC
2023, 2020 FBC
2022 CBC
CCRR-0351


FLORIDA PRODUCT APPROVAL
Report No. Product Covered    
FL No. 31342 Tesla Solarglass Roof
Listing Report Return to Search
Attributes
CriteriaFM 4473 (2011)
CriteriaUL 790 (2004) Ed. 8 (R2018)
CriteriaTAS 100 (2023)
CriteriaASTM D3161/D3161M:2020
CSI Code07 32 00 Roof Tiles
Listing SectionROOF COVERING SYSTEMS
Spec ID52115
Design Documents
No Results
Code Compliance Research Reports
Public Documents
No Results