PRODUCT DESCRIPTION
Total Door II Specialty Elevator Door Frame for use in front of elevator doors. The assembly utilizes a steel faced (16, 18, 20 gauge) polystyrene or mineral core swinging flush door for installation in up to and including 90 minute applications. For use in a listed proprietary (3 sided) 16 gauge steel frame. The door leaves are hung on a proprietary continuous hinge system and sealed at the meeting edge with a proprietary interlocking system. The head of the door is sealed with a bulb seal and the bottom of the door is sealed with a smoke seal attached to the door with a stainless steel or aluminum bracket. Standard pairs must have equal sized door leaves or unequal leaves with the one leaf having a minimum width of 18 inches.
Size Limitation:
Maximum Nominal Width: 58-1/4"
Maximum Nominal Height: 101-1/8"
Dimensions |
Configuration |
Width |
Height |
Clear Opening |
58-1/4" |
101-1/8" |
Overall Frame |
64-1/4" |
104-1/8" |
Limitations*: The following proprietary components are provided with the system: Latches & Hinge System, Frame/Surface-Mounted Closers, Concealed Closer Arms, Surface-Mounted Protection Plates, Viewer, Surface Mounted or Mortised Door Bottoms. Metal Edge or Astragal is not required.
*Additional information is provided in the manufacturer's installation instructions for smoke and draft control size restrictions and limitations.
Ratings Achieved
The product noted above has been tested and qualified for fire resistance ratings per UL 10C, NFPA 252, and CAN / ULC S104 up to and including 90 minute applications. Temperature rise is greater than 650ºF at 30 minutes on polystyrene core doors and less than 250°F at 30 minutes on mineral core doors.
The assembly has been tested in accordance with UL 1784. Results were achieved at four differential pressures ranging from 0.05 to 0.3 in. water column (12 to 75 Pa).
Standard/Code Section |
Property |
Results |
UL 1784 |
Maximum air leakage at 0.05, 0.1, 0.2 and 0.3 inches of water column differential at ambient and elevated (400°F) temperature. |
< 3.0 cfm/ft2 |
Note: This assembly was tested without an artificial bottom seal. The assembly may be installed in areas where pressurization is provided to control smoke movement in accordance with Section 4.3.2 of NFPA 105 (2019) and for hoistway opening protection and lobby doorways as allowed in Chapter 30 of the 2018 IBC.