Intertek Directory of Building Products

Door Components 20-90 Minute Steel Fire Door Frame Company: DCI Hollow Metal

Rolled Formed Steel Door Frame (20or 18 gauge) (Knock-Down) for installation in single swing applications up to 90 minute locations in steel/wood stud drywall openings.
 
Rating Max. Size Wall Construction Minimum Wall Thickness Door Type
20-60 Minute Singles: 4'-0" wide x 8'-0" high
Standard Pairs: Not Allowed
Double Egress: Not Allowed
Steel/Wood Stud Drywall 3 1/2" Steel/Wood
90 Minute Singles: 4'-0" wide x 8'-0" high
Standard Pairs: Not Allowed
Double Egress: Not Allowed
Steel/Wood Stud Drywall 6” Steel/Wood
 
* Frame must be sealed to the wall with gypsum compound.
**See manufacturer's installation instructions for additional information, restrictions and limitations.
 
Testing Standards
UL-10C (Positive Pressure).
Evaluated to the following...
This category includes frames not based on UL-63 construction Type (such as aluminum, wood, light gauge steel, composite, etc.). These listings will reference specific door types for which each frame is qualified. All frames listed in this section may be used in positive pressure assemblies per the terms and limitations of the individual listing.
All frames in this category are identified by a label or marking bearing the wording, "Listed Fire Door Frame", the Warnock Hersey Certification Mark, UL-10C. Frames rated at less than 3 hours will have a time interval noted on the label/marking.
Listing Report Return to Search
Attributes
CriteriaCAN / ULC S104 (2015) (R2020)
CriteriaUL 10(c) (2016)
CriteriaNFPA 252 (2017)
CSI Code08 11 00 Metal Doors and Frames
Fire Resistance20 Min PP Category C Proprietary Frame
Fire Resistance45 Min PP Category C Proprietary Frame
Fire Resistance60 Min PP Category C Proprietary Frame
Fire Resistance90 Min PP Category C Proprietary Frame
Listing SectionCATEGORY C - PROPRIETARY FRAMES
Spec ID53893
SwingSingle Swing
Design Documents
No Results
Public Documents
No Results