Intertek Directory of Building Products

TruStile 20 Min Wood Door NP/PP Company: TruStile Doors, LLC

Panel Type (Proprietary Construction) Wood Fire Door for installation in 20 minute (with hose stream) locations in any "Category C - Standard" Frame.

Limitations: Cylindrical or Mortise Latches with minimum 1/2" Bolt Throw and 2-3/4" Backset/Surface-Mounted Vertical Rods Fire Exit Hardware/Surface-Mounted Fire Exit Hardware/Surface-Mounted Bolts/Surface-Mounted Closer/Viewer/Kickplates/Concealed or Surface Mounted Door Bottoms, Mortised Manual Flush Bolts and Auto Flush Bolts (DCI Model # 960/962).
 
Configuration Maximum Size
Single Swing 4'0" wide x 8'0" high
3'0"wide x 8'6" high
Standard Pairs 8'0" wide x 8'0" high

Evaluated to the Following:

This category includes doors evaluated without an edge-sealing system between the door and frame. It also includes doors evaluated with a sealing system incorporated (concealed or visible) into the edge of the door by the licensed manufacturer or machining distributor.

Meeting edges of pairs may require an astragal or an edge-sealing system. Please refer to individual door listings.

These doors are eligible for use in any "Category C - Standard" frame. These doors may also be installed in frames listed in "Category C - Proprietary" in the accordance with the frame manufacturer's individual listing.

All doors listed in Category A are eligible to bear the "S" (for Smoke & Draft Control assemblies) if a listed "Category H - Smoke & Draft Control Gasket" has been applied to the assembly. Please refer to Category H for individual gasket manufacturer's listings.

All doors in this category are identified by a label or marking bearing the wording, "Listed Fire Door", a time interval, a temperature rise rating, a serial number and the Warnock Hersey Certification Mark and Standard(s)".
Listing Report Return to Search
Attributes
CriteriaCAN / ULC S104 (2015) (R2020)
CriteriaUL 10(c) (2016)
CriteriaUL 10(b) (2008) (R2015)
CriteriaNFPA 252 (2017)
CSI Code08 10 00 Doors and Frames
CSI Code08 14 00 Wood Doors
Fire Resistance20 Min w/Hose Stream PP Cat A Door
Fire Resistance20 Min w/out Hose Stream NP
GlazingVision Panel
Listing SectionCATEGORY A - DOORS - NO ADDITIONAL EDGE-SEALING SYSTEM REQUIRED
Spec ID53993
SwingSingle Swing
SwingStandard Pairs