University Series Fixed Window Frame & Transom. Hot Rolled Steel fire window frames with welded corners. Fixed windows & transoms for installation in 45 minute application in steel stud drywall openings.
| Fixed Window Maximum Dimensions |
| Overall Width: |
43-1/2” |
| Overall Height: |
90” |
| Clear View Width: |
39-1/2” |
| Clear View Height: |
86” |
| Visible Area: |
3,397 in2 |
| Minimum Stop Height: |
5/8” |
| Transom Maximum Dimensions |
| Overall Width: |
74-3/4” |
| Overall Height: |
19” |
| Clear View Width: |
71-7/8” |
| Clear View Height: |
16-1/8” |
| Visible Area: |
1,160 in2 |
| Minimum Stop Height: |
5/8” |
Note: The maximum dimensions above are Hope’s limitations for glass. The final size must be determined between the glass manufacturer’s size limitations and Hope’s limitations, whichever is smaller.
| Fixed Window Frame & Transom Limitations |
| Minimum Web Thickness: |
0.160” |
| Glazing Rebate Minimum: |
3/8” wide |
| Outside Flange/Leg: |
1-1/4” tall |
| Inside Flange/Leg: |
5/8” tall |