INFERNOGARD™ Fire Rated Door System 90 Minute Company: Isoclima Specialty Glass LLC

INFERNOGARD™ Door Assembly System
Assembly Rating - Up To 90 Minutes
 
Rating: Application: Maximum Size of Openings:
60 Minute Singles  4' 0" wide x 9' 0" high
Pairs  8' 0" wide x 9' 0" high
90 Minute Singles  4' 0" wide x 9' 0" high
Pairs  8' 0" wide x 9' 0" high
 
Glazing Markings:  D-H-T-60 and D-H-T-90
 
*Component Bearing the Warnock Hersey Certification Mark
 
Limitations:
 
Surface Mounted Vertical Rod Fire Exit Hardware, Pivot Hinges, Offset Hinges.
 
Panels - 4,952 sq. in. (1 hour), 4,876 sq. in. (1-1/2 hour).
 
Temp Rise - 250°F for full duration, Door and frame to be installed as a unit.
 
Listed fire-rated open cell glazing tape is allowed for use with INFERNOGARD™ Glazing such that it is approved for fire-rated durations equal to or greater than the respective INFERNOGARD™ Glazing product it is used with.
 
Due to the thickness of the INFERNOGARD™ products, the vision kit and door assembly must be fire rated and listed and labeled for use with fire rated glazings which are at least of equivalent thickness to the respective INFERNOGARD™ products used.
 
Note: This listing is in regard to fire resistance only.
 
Listing Report Return to Search
Attributes
CriteriaCAN / ULC S104 (2015) (R2020)
CriteriaUL 10(c) (2016)
CriteriaNFPA 252 (2017)
CSI Code08 11 00 Metal Doors and Frames
Fire Resistance90 Min Positive Pressure
Listing SectionCATEGORY D - DOOR/FRAME ASSEMBLIES
Spec ID56532