DeanSteel DSPROJ 180 Minute Fire Door Company: Deansteel Manufacturing Company, Inc.

FIRE RESISTANT PRODUCTS & COMPONENTS

CATEGORY A DOORS - NO ADDITIONAL EDGE-SEALING SYSTEM REQUIRED

PRODUCT COVERED
DeanSteel  DSPROJ 3 Hour Fire Door, Hollow Metal Type (16,18, & 20 gauge faces) (Paper Honeycomb Core, or Polystyrene)

PRODUCT DESCRIPTION
Hardware Limitations:  Cylindrical / Cylindrical with Deadbolt / Mortise / Card Reader / Rim-Type Surface Mounted Fire Exit Devices / Surface Mounted Door Bottoms / Surface Mounted Closers/ Viewer / 16" Protection Plates.

Temperature Rise - Greater than 650°F at 30 minutes. 
 
Configuration Maximum Size
Single Swing 4’-0” wide by 8’-0” tall
Standard Pairs 8’-0” wide by 7’-2” tall
Double Egress Not Allowed

Vision Panels
Door Fire Rating Maximum
Visible Area
(square inches)
Maximum
Visible Width
(inches)
Maximum
Visible Height
(inches)
Glazing Materials
20 Minutes 1296 54 54 Listed and labeled glazing materials
20 Minutes 2856 34 84 Pilkington ¼” thick wired glass1 or listed ceramic glazing
20 Minutes
(Without Hose)
2971 35.75 81.125 Listed and labeled glazing materials
45 Minutes 1296 54 54 Listed and labeled glazing materials
45 Minutes 2856 34 84 Pilkington ¼” thick wired glass or listed ceramic glazing
60 Minutes 100 33 33 Listed and labeled glazing materials
60 Minutes 552 2. 18 36 Pilkington ¼” thick wired glass1 or listed ceramic glazing
90 Minutes 100 33 33 Listed and labeled glazing materials
90 Minutes 552 2. 18 36 Pilkington ¼” thick wired glass1. or listed ceramic glazing
3 Hour 100 33 33 FireLite or FireLite Plus or listed  3 hr ceramic glazing
Footnotes:
1. Listed and labeled Pilkington ¼” thick wired installed into “VL3000” (by Air Louvers Inc) or “TG4” (by Leslie-Locke Inc.) used with PEMKO’s "FG 3000 Fire Glaze" glazing compound.
2. Each door leaf can have up to four (4) vision panels, each with a maximum of 552 square inches clear view area. 

The product noted above has been tested and qualified per UL 10B, UL 10C, NFPA 252, and CAN / ULC S104 for a 3 Hour Positive Pressure Fire Rating.  

These doors are eligible for use in any "Category C - Standard" frame. These doors may also be installed in frames listed in "Category C - Proprietary" in the accordance with the frame manufacturer's individual listing.

The door noted above is eligible to bear the "S" (for Smoke & Draft Control assemblies) if a listed "Category H - Smoke & Draft Control Gasket" has been applied to the assembly. Please refer to Category H for individual gasket manufacturer's listings.
        

Evaluated to the following...
Unless otherwise noted, assemblies in this section have been evaluated for conformance to the following standards:
CAN/ULC-S104, Standard Method for Fire Tests of Door Assemblies
NFPA-252, Standard Methods for Fire Tests of Door Assemblies
UL-10(b), Fire Tests of Door Assemblies
UL-10(c), Fire Tests of Swinging Door Assemblies
and are installed in accordance with the following:
NFPA-80, Fire Doors and Windows
Manufacturer's Instructions
All assemblies are identified by a label or marking bearing the wording, "Listed (Product)", a time interval, temperature rise (if applicable), a serial number and the Intertek WH Certification Mark.

Unless otherwise specified, the Fire Doors referenced above have a minimum thickness of 1-3/4".  
Listing Report Return to Search
Attributes
CriteriaUL 10(b) (2008) (R2009)
CriteriaCAN / ULC S104 (2015) (R2020)
CriteriaUL 10(c) (2016) Ed. 3 (R:27 May 2021)
CriteriaNFPA 252 (2022)
CSI Code08 11 00 Metal Doors and Frames
CSI Code08 11 13 Hollow Metal Doors and Frames
Fire Resistance45 Min Neutral Pressure
Fire Resistance90 Min Neutral Pressure
Fire Resistance3 Hour Neutral Pressure
Fire Resistance60 Min Neutral Pressure
Fire Resistance45 Min Positive Pressure
Fire Resistance90 Min Positive Pressure
Fire Resistance60 Min Positive Pressure
Fire Resistance3 Hour Positive Pressure