Intertek Directory of Building Products

James Hardie - Hardie® Architectural Panels Company: James Hardie Building Products, Inc.

Hardie® Architectural Panels (textured/nontextured, HZ5/HZ10) are fiber cement panel siding measuring 96, 120 or 144 inches long x 48 inches wide x 5/16 inches thick. The panels have a nominal weight of 2.3 lb/ft2.

PHYSICAL RATINGS
Standard Rating
ASTM C1186 Meets Grade II, Type A
BS EN 12467 Meets Category A, Class 2, Level I
ISO 8336 Meets Category A, Class 2, Level I

FLAME SPREAD RATINGS 
Standard Flame Spread Index Smoke Developed Index
ASTM E84 0 0
CAN/ULC S102 0 0

FIRE RATINGS
Product Standard Rating Design Listing Number
Hardie® Architectural Panels (textured/
nontextured, HZ5/HZ10)
ASTM E136 Non-combustible N/A
CAN/ULC S114 Non-combustible N/A
ASTM E119
CAN/ULC S101
 1 Hour      JH/FCS 60-01
JH/FCS 60-02
JH/FCS 60-03
JH/FCS 60-04
2 Hours JH/FCS 120-01
JH/FCS 120-02


STRUCTURAL RATINGS
Structural rating per ASTM E330:

 
System No.  #1
Results:
Details: 
Ultimate Load: 112 psf
Framing: Nominal 2x4 No. 2 SPF or BTR Lumber 
Stud spacing: 16 in. on center 
Fasteners: 16 gauge 1-1/2 in. stainless finish nails. 
Fastener Spacing: 4 in. on center along studs. 
  #2
Results:
Details
Ultimate Load: 128 psf
Framing: Nominal 2x4 No. 2 SPF or BTR Lumber  with 7/16 in. thick Wood Structural Panel sheathing attached per applicable Code. 
Stud spacing: 16 in. on center
Fastener: 16 gauge 1-1/2 in. stainless finish nails.
Fastener spacing: 4 in. on center along studs and 4 in. on center along panel edges where panel edges may be attached to sheathing only. 
  #3
Results:
Details
Ultimate Load: 87.1 psf
Framing: Nominal 2x4 No.1 or better Douglas Fir
Stud spacing: 24 in. on center
Fastener: 16 gauge 1-1/2 in. stainless finish nails
Fastener spacing: 4 in. on center along studs
  #4
Results:
Details
Ultimate Load: 88.2 psf
Framing: Nominal 2x4 No.1 or better Douglas Fir
Stud spacing: 24 in. on center
Fastener: 0.09 in x 1-1/2 in. 4d stainless steel ring shank siding nails
Fastener spacing: 4 in. on center along studs
 
FLORIDA PRODUCT APPROVAL
Report No. Product Covered
FL No. 13223 Hardie® Architectural Panels
FL No. 32103  Hardie® Textured Panels
Listing Report Return to Search
Attributes
CriteriaCAN / ULC S114 (2005)
CriteriaASTM E331 (2000) (R2016)
CriteriaCAN / ULC S101 (2014)
CriteriaASTM E119 (2015)
CriteriaASTM E330 (2014) (R2021)
CriteriaASTM E331 (2000) (R2009)
CriteriaASTM C1186 (2008) (R2016)
CriteriaISO 8336:2017 Ed.3
CriteriaASTM E136 (2019) Ed.a
CriteriaASTM C1186 (2022) E1
CriteriaISO 8336 (2009)
CriteriaEN 12467:2012 +A1
CriteriaASTM E84 (2016)
CriteriaASTM E136 (2016) Ed.16a
CriteriaASTM E119 (2016)
CriteriaASTM E84-18
CSI Code07 46 00 Siding
Listing SectionWALL ASSEMBLIES
Spec ID57657
Design Documents
Public Documents
No Results