Intertek Directory of Building Products

Foam Supplies, Inc. genfoamâ„¢ OC Spray-applied Polyurethane Foam Plastic Insulation Company: Foam Supplies, Inc. Code Compliance Research Reports: CCRR-0389

Foam Supplies, Inc. genfoam™ OC is a two-component, open cell, spray-applied polyurethane foam plastic with a nominal in-place density of 0.52 pcf. The insulation is produced in the field by combining a polymeric isocyanate (A component) with a resin (B component).

The insulation meets the requirements of Mandatory Testing and selected Optional Testing of ICC-ES Acceptance Criteria for Spray-applied Foam Plastic Insulation (AC377) for a low-density insulation as described in Code Compliance Research Report CCRR-0389.

FLAME SPREAD RATINGS
Test Standard               Flame Spread Index           Smoke Developed Index      
ASTM E84 25 or less 450 or less


FIRE RATINGS
Test Standard Configuration / Details    Rating
NFPA 286 See CCRR-0389 Met acceptance criteria of
IBC Section 8903.1.1.1 and
IRC Section R302.9.4 as
configured
ICC-ES AC377 Appendix X See CCRR-0389 Met requirements as
configured


CODE COMPLIANCE RESEARCH REPORT
     Evaluation Method           Building Code           CCRR Number     
ICC-ES AC377 2021, 2018, 2015 IBC
2021, 2018, 2015 IRC
2021, 2018, 2015 IECC
CCRR-0389
Listing Report Return to Search
Attributes
CriteriaNFPA 286 (2015)
CriteriaASTM E84 (2018b)
CriteriaICC-ES AC377 (April 2020)
CSI Code07 21 00 Thermal Insulation
CSI Code07 21 19 Foamed-In-Place Insulation
Listing SectionBUILDING MATERIALS WITH SURFACE BURNING CHARACTERISTICS
Spec ID58341
Design Documents
No Results
Code Compliance Research Reports
Public Documents