Foam Supplies, Inc. genX™ Spray-applied Polyurethane Foam Plastic Insulation Company: Foam Supplies, Inc. Code Compliance Research Reports: CCRR-0390

Foam Supplies, Inc. genX™ insulation is a two-component, open cell, spray-applied polyurethane foam plastic.  The insulation has a nominal in-place density of 0.55 pcf.  The insulation is produced in the field by combining a polymeric isocyanate (A component) with a resin (B component).

The insulation meets the requirements of Mandatory Testing and selected Optional Testing of ICC-ES Acceptance Criteria for Spray-applied Foam Plastic Insulation (AC377) for a low-density insulation as described in Code Compliance Research Report CCRR-0390.

FLAME SPREAD RATINGS
  Test Standard     Flame Spread Index     Smoke Developed Index  
ASTM E84 25 or less 450 or less


FIRE RATINGS
Test Standard Configuration / Details Rating
NFPA 286 See CCRR-0390 Met acceptance criteria of
IBC Section 8903.1.1.1 and
IRC Section R302.9.4 as
configured
ICC-ES AC377 Appendix X See CCRR-0390 Met requirements as
configured


CODE COMPLIANCE RESEARCH REPORT
    Evaluation Method          Building Code         CCRR Number    
ICC-ES AC377 2024, 2021, 2018 IBC
2024, 2021, 2018 IRC
2024, 2021, 2018 IECC
CCRR-0390
Listing Report Return to Search
Attributes
CriteriaASTM E84 (2016)
CriteriaICC-ES AC377 (February 2020)
CriteriaASTM E84 (2021a)
CSI Code07 21 00 Thermal Insulation
CSI Code07 21 19 Foamed-In-Place Insulation
Listing SectionBUILDING MATERIALS WITH SURFACE BURNING CHARACTERISTICS