DESCRIPTION
The non-loadbearing Mada Gypsum suspended ceiling assembly comprises of double layers of 16mm Mada Plus Fire Resistant (FR) Plasterboards screw-attached to the underside of the suspended ceiling assembly framing system. The suspended ceiling assembly framing system consists of Mada Wall Angles, Mada Main channels and Mada Furring channels.

The 60-minute suspended ceiling assembly has been tested in accordance with
EN 1364-2:2018
Full details of the assembly are available in the design listing ref. MGC/GBF 60-09.

FIRE RATINGS
Test Standard Rating Design Number
EN 1364-2:2018 Integrity (E): 70 minutes
Insulation (I): 69 minutes
MGC/GBF 60-09

Note: The fire rating is only valid with the Mada Plus Fire Resistant (FR) plasterboard layer exposed to the fire from the bottom side with the mineral wool insulation layer on the non-fire side.

Field of direct application of test results:
1. The test results apply to ceiling of any dimension provided that the distribution of hangers is not reduced, and the distance between the hangers is not increased. The distance between grid members and the load on the hanger, shall not be increased. 
2. The test results are valid for cavities of any height. The test results are applicable to ceilings suspended by hangers of any length.
3. The test results are only applicable to the inclusion of cables. Pipes, etc. above the ceiling provided they are installed in such a manner that they give no additional mechanical load to the ceiling.
4. The test specimen was tested without any fittings, so the final assemblies are not allowed to include any fittings. Addition of any fittings requires further evaluation.
Listing Report Certificate of Compliance Return to Search
Attributes
Certificate Date of ExpiryDecember 31, 2026
Certificate Date of Initial RegistrationJanuary 04, 2021
Certificate NumberWHI21-6623623
CriteriaEN 1364-2 (2018)
CSI Code09 50 00 Ceilings
CSI Code09 29 00 Gypsum Board
Fire Resistance1 Hour Fire Rating
Listing SectionROOF/CEILING, FLOOR/CEILING, BEAM & COLUMN ASSEMBLIES