Therma Tru Corporation - 650 Gasket, 740 Gasket & 928 Gasket - Category H & J Gaskets Company: Therma Tru Corporation

Product Covered:
Therma Tru Corporation - Category H & J Gaskets

Product Description:
Gasket Models below for installation with Listed Steel or Wood Door Frames and Listed Steel or Wood or Fiberglass Faced Fire Doors. Listed Category "H" or "J" Gaskets for use on kerfed frames between door and frame interface. 

Note: All other requirments and limitations specified in the door or frame listing still apply.

Model
- Therma Tru Corporation's 650 Gasket
- Therma Tru Corporation's 740 Gasket
- Therma Tru Corporation's 928 Gasket

Configuration Maximum Size
Single Swing 4'0" wide x 10'0" high
Pairs 8'0" wide x 10'0" high

Air Leakage Ratings
Pressure (inches H2O) Maximum Leakage Rate
(scfm/ft2)
Ambient temperature*
Maximum Leakage Rate
(scfm/ft2)
Elevated temperature
(400°F)*
0.05 0.18 0.16
0.10 0.33 0.34
0.20 0.60 0.63
0.30 0.73 0.73
*The door assemblies may be installed without a gasket or seal at the bottom of the assembly except where the assembly is installed where pressurization is provided to control smoke movement. The gap between the bottom of the assembly and the finished floor shall be a maximum of 3/8 in., based on the requirements for fire resistance applications.
 
Standard/Code Section Property Results
UL 1784 Max. air leakage at 0.3 in. of w.c. pressure differential at ambient and elevated (400°F) <3.0/cfmft2
2018, 2015 & 2012 IBC Section 710.5.2.2,
2009 IBC Section 711.5.2
Max. air leakage: < 3 cfm per sq.ft. of opening at 0.1 in. of w.c. pressure differential at ambient temperature and elevated (400 degrees F.) Complies

Evaluated to the following:
 
Doors constructed as described in this procedure meet the requirements for both positive and neutral pressure fire tests, UL 10C, NFPA 252 and CAN/ULC S104 with hose stream and certified to UL 1784 for air leakage.
Listing Report Return to Search
Attributes
CriteriaUL 1784 (2015)
CriteriaCAN / ULC S104 (2015) (R2020)
CriteriaUL 10(c) (2016)
CriteriaNFPA 252 (2017)
CSI Code07 80 00 Fire and Smoke Protection
Fire Resistance20 Min Category J Gasketing
Listing SectionCATEGORY H - SMOKE & DRAFT CONTROL GASKETING
Listing SectionCATEGORY J - GASKETING