Curries 507 Series - Fire Doors - Machining
Company: Curries Company
PRODUCTS COVERED
Swinging type fire doors with a honeycomb core, single swing doors and pair of doors swinging in the same direction, double egress doors, single swing Dutch doors, rated 20 minutes up to and including 3 hours. The doors are identified by the following model names: "507 Series".
Swinging fire doors with a foamed-in-place polyurethane foam or polystyrene slab foam cores that are classified in accordance with UL10C. Doors are rated up to and including 3 hours. The doors are identified by the following model name: "507 Series".
PRODUCT LISTINGS FOR CATEGORY A - DOORS - NO ADDITIONAL EDGE-SEALING SYSTEM REQUIRED
Steel-Faced (16, 18 gauge) (507 Series) (Honeycomb Core Type), Swinging Flush Door for installation in 3 hour locations. For use in listed (3-sided) 16 gauge welded steel frames meeting UL-63 or as per frame manufacturer's listing(s).
Limitations*: Mortise or Cylindrical Latches with maximum 5” backset/Mortised Exit Devices/Surface-Mounted Vertical Rod fire exit devices/Rim-Type fire exit devices/Concealed Vertical Rod exit devices/Deadbolts/Extension Bolts with maximum extension of 24”/Surface Bolts/Automatic Flush Bolts/Surface-Mounted Closers/Surface-mounted Protection Plates/Louver/Vision Light Kit - Maximum 100 in2 (3 hour)/Vision Light Kit - Maximum 1296 in2 (1/3, 3/4, 1, 1-1/2 hour)/Surface Mounted or Mortised Door Bottoms/Astragal Required on Pairs (3 hour)/Astragal Optional (1-1/2 hour)/Temperature Rise - Greater than 650°F at 30 minutes.
Configuration |
Maximum Size* |
Single Swing |
4’-0” wide by 9’-0” high |
Standard Pairs |
8’-0” wide by 9’-0” high (1-1/2 hour)
8’-0” wide by 8’-0” high (3 hour) |
Double Egress |
8’-0” wide by 9’-0” high (1-1/2 hour)
8’-0” wide by 7’-2” high (3 hour) |
Steel-Faced (14, 16, 18, 20, 22, 24 gauge) (507 Series) (Honeycomb Core Type), Swinging Flush Door for installation in 3 hour locations. For use in listed (3-sided) 16 gauge welded frames meeting UL-63 or as per frame manufacturer's listing(s).
Limitations*: Mortise or Cylindrical Latches with maximum 5” backset/Mortised Exit Devices/Surface-Mounted Vertical Rod fire exit devices/Rim-Type fire exit devices/Concealed Vertical Rod exit devices/Deadbolts/Surface Bolts/Surface-Mounted Closers/Surface-Mounted Protection Plates/Louver/Vision Light Kit Maximum 100 in2 (3 hour)/Vision Light Kit - Maximum 1296 in2 (1/3, 3/4, 1,1-1/2 hour)/Surface-Mounted or Mortised Door Bottoms/Temperature Rise - Greater than 650°F at 30 minutes.
Configuration |
Maximum Size*
14, 16, 18 gauge |
Maximum Size*
20 gauge |
Maximum Size*
22, 24 gauge |
Single Swing |
4’-0” wide by 9’-0” high |
4’-0” wide by 8’-0” high |
3’-0” wide by 7’-0” high |
Standard Pairs |
N/A |
N/A |
N/A |
Double Egress |
N/A |
N/A |
N/A |
Steel-Faced (20, 22, 24 gauge) (507 Series) (Honeycomb Core Type), Swinging Flush Door for installation in 1-1/2 hour locations. For use in listed (3-sided) 16 gauge welded steel frames meeting UL-63 or as per frame manufacturer's listing(s).
Limitations*: Mortise or Cylindrical Latches with maximum 5” backset/Mortised Exit Devices/Surface-Mounted Vertical Rod fire exit devices/Rim-Type fire exit devices/Concealed Vertical Rod exit devices/Deadbolts/Extension Bolts with a maximum extension of 24”/Surface Bolts/Automatic Flush Bolts/Surface-Mounted Closers/Surface-Mounted Protection Plates/Louver/Vision Light Kit - Maximum 1296 in2 (1/3, 3/4, 1, 1-1/2 hour)/Surface-Mounted or Mortised Door Bottoms/Astragal Required on Pairs/Temperature Rise - Greater than 650°F at 30 minutes.
Configuration |
Maximum Size* |
Maximum Size* |
Single Swing |
4’-0” wide by 8’-0” high |
3’-0” wide by 7’-0” high |
Standard Pairs |
8’-0” wide by 8’-0” high |
6’-0” wide by 7’-0” high |
Double Egress |
N/A |
N/A |
Steel-Faced (16, 18 gauge) (Honeycomb Core Type), Swinging Flush Door for installation in 3 hour locations. For use in listed (3-sided) 16 gauge welded steel frames meeting UL-63 or as per frame manufacturer's listing(s).
Limitations*: Bottom Leaf Cylindrical Latches with maximum 5” backset/Top Leaf Surface Bolts/Surface-Mounted Closers/Surface-mounted Protection Plates/Surface Mounted or Mortised Door Bottoms/Horizontal Astragal Required/Temperature Rise Greater than 650°F at 30 minutes.
Configuration |
Maximum Size* |
Single Swing |
4’-0” wide by 7’-2” high |
Standard Pairs |
N/A |
Double Egress |
N/A |
*See manufacturer's installation instructions for additional information on Smoke and Draft Control, size restrictions and limitations.
EVALUATED TO THE FOLLOWING...
This category includes doors evaluated without an edge-sealing system between the door and frame. It also includes doors evaluated with a sealing system incorporated (concealed or visible) into the edge of the door by the licensed manufacturer or machining distributor.
Meeting edges of pairs may require an astragal or an edge-sealing system. Please refer to individual door listings.
These doors are eligible for use in any "Category C - Standard" frame. These doors may also be installed in frames listed in "Category C - Proprietary" in the accordance with the frame manufacturer's individual listing.
All doors listed in Category A are eligible to bear the "S" (for Smoke & Draft Control assemblies) if a listed "Category H - Smoke & Draft Control Gasket" has been applied to the assembly. Please refer to Category H for individual gasket manufacturer's listings.
All doors in this category are identified by a label or marking bearing the wording, "Listed Fire Door", a time interval, a temperature rise rating, a serial number, and the Warnock Hersey Certification Mark and "UL 10C".