Johnson Gas Mendota Model FV32I Direct Vent Gas Fireplace Insert Company: Johnson Gas Appliance Company

PRODUCT DESCRIPTION
Product Direct Vent Gas Fireplace Insert
Brand Name Mendota
Description The model FV32I is a direct vented gas fireplace insert suitable for use with natural gas or propane.  The unit is factory installed for use with natural gas.  A gas appliance conversion kit is provided to convert the fireplace to propane.
The model FV32I feature an automatic intermittent/standing pilot ignition system.  A remote control is provided with the appliance to turn the fireplace off and on.
Models FV32I
Model Similarity None
Ratings 120V, 60Hz, 1.5A

APPLIANCE RATINGS
  NATURAL GAS PROPANE
Model FV32I
Input rating(Btu/hr) 0-610 m 31,000 31,000
Input rating(Btu/hr) 610-1370 mm 31,000 31,000
Minimum input (Btu/hr) 0-1370 m 10,597 12,004
Orifice Size(DMS) 0-610 m F45/R49 F&R 3/64”
Orifice Size(DMS) 610-1370 m F45/R49 F&R 3/64”
Manifold pressure (in. w.c./kPa) normal 3.5/0.87 10.0/2.50
Manifold pressure (in. w.c./kPa) reduced 1.6/0.40 6.4/1.59
Manifold pressure (in. w.c./kPa) 610-1370m 4.8/1.2 11.9/2.96
Minimum inlet pressure (in. w.c./kPa 5/1.24 11.0/2.74

VENTING INFORMATION
Any combination of rise and run may be used if it is within the boundaries indicated below. The total vent length shall not exceed 50 feet. Refer to the Owner’s Manual for more details on the permissible venting configurations.
VENTING
Vent Type Co-axial
Vent Size 3-in x 3-in
Max. Vertical Length 50-ft
Min. Vertical Length 10-ft
Max. Number of Elbows None

CLEARANCES TO COMBUSTIBLE CONSTRUCTION
FIREPLACE CLEARANCES
4-in Mantle from Floor 33.75-in/857 mm
Sidewall 18-in/457 mm

An insulated non-combustible protective cover with a minimum R-value of 1.0 must be placed in front of the appliance at a minimum of 16-inches from the front.
Listing Report Return to Search
Attributes
CriteriaANSI Z21.88 / CSA 2.33 (2019) (R2024)
CSI Code10 30 00 Fireplaces and Stoves
Fuel TypePropane
Fuel TypeNatural Gas
Listing SectionGAS-FIRED VENTED ROOM HEATERS