PRODUCT DESCRIPTION
RACO Solutions II frames are extruded aluminum frames for use in smoke and draft control assemblies. The frames contain a kerf-mounted silicone perimeter bulb seal and may be used with RACO 250 (Narrow Stile), 400 (Medium Stile), or 550 (Wide Stile) Series Commercial Interior Aluminum and Glass Doors. The glazed aluminum doors are constructed of extruded aluminum cellular construction with a mechanically attached aluminum glazing stop. Glazing must be minimum 1/4-inch-thick monolithic glass and must be sealed on both sides with a silicone gasket.
The frames may also be used with third-party wood doors that bear an independent label denoting compliance with UL 10C. Any modification to a third-party wood door must be in compliance with that door's UL 10C certification. An "S" label applied to the frame shall cover both the frame and third-party wood door when the following requirements are met:
MINIMUM (TESTED) SIZE:
Single:
Width - 3'-0"
Height - 7'-0"
Pair:
Width - 6'-0"
Height - 7'-0"
MAXIMUM SIZE:
Single:
Width - 4'-0"
Height - 9'-0"
Pair:
Width - 8'-0"
Height - 9'-0"
ASSEMBLY DETAILS:
Glazed Doors - RACO 250/400/550 Series Commercial Interior Aluminum and Glass Doors
Wood Doors - Third-party Door Bearing an Independent Label Denoting Compliance with UL 10C
Hinges - Standard Weight Butt or Continuous
Latching Hardware - Cylindrical, Single-point Mortise, or Concealed Vertical Rod Mortise
Latching Hardware (inactive door) - Extension flush bolts (top of door only, may not interfere with meeting edge gasket)
Closers - Surface Mount or Inverted LCN 3130
Perimeter Gasket - Kerf-mounted Silicone Bulb
Meeting Edge Gasket (Pairs) - Single Row NGP 5060C
Door Bottom (RACO Glazed Aluminum Doors) - NGP 320S Automatic Door Bottom Required
Door Bottom (Third-party Wood Doors) - Not Required (See Installation Restrictions Below)
Frame Installation - Throated or Abutted Configuration. With or Without Silicone Sealant
Sidelights - Allowed when sealed against the passage of smoke at temperatures up to 400ºF
AIR LEAKAGE RATINGS - WHEN USED WITH RACO GLAZED ALUMINUM DOORS
| Test Standard |
Test Type |
Rating* |
| UL 1784 |
Ambient Temperature |
≤3.0 cfm/ft2 at up to 0.10 in. of w.c. |
| UL 1784 |
Elevated Temperature |
≤3.0 cfm/ft2 at up to 0.10 in. of w.c. |
*These assemblies were tested without an artificial bottom seal using an NGP 320S automatic door bottom. The assembly, including the NGP 320S automatic door bottom, may be installed in areas where pressurization is provided to control smoke movement in accordance with Section 4.3.2 of NFPA 105 (2019).
AIR LEAKAGE RATINGS - WHEN USED WITH THIRD-PARTY WOOD FIRE DOORS
| Test Standard |
Test Type |
Rating* |
| UL 1784 |
Ambient Temperature |
≤3.0 cfm/ft2 at up to 0.10 in. of w.c. |
| UL 1784 |
Elevated Temperature |
≤3.0 cfm/ft2 at up to 0.10 in. of w.c. |
*These assemblies were evaluated with an artificial bottom seal. The assemblies are not to be installed in areas where pressurization is provided to control smoke movement in accordance with Section 4.3.2 of NFPA 105 (2019) or for hoistway opening protection and lobby doorways where prohibited in Chapter 30 of the 2018 IBC.