Intertek Directory of Building Products

PS Industries Incorporated - HYDRO1-PD520 and HYDRO1-PD522 Windstorm-resistant Door and Frame Assembly Company: PS Industries Incorporated

The PS Industries Incorporated HYDRO1-PD520 and HYDRO1-PD522 Pedestrian Flood Doors are single-swing, windstorm-resistant, pedestrian egress doors. The HYDRO1-PD522 includes passive fire pins at the hinge location for fire resistance. Fire resistance is outside the scope of this listing, see Intertek Listing 37148 for fire ratings and limitations.

ASSEMBLY DETAILS
Maximum Size - 4'0" wide by 8'0" high
Door - 16-gauge steel faced, horizontally stiffened
Hinge - Select Hinges SL21 continuous aluminum geared hinge
Latching Hardware - Von Duprin 98F Rim Exit
Perimeter Seal - Proprietary PS Industries Perimeter Gasket
Frame - Minimum 14-gauge steel, fully grouted jambs
Anchoring - Minimum 3/8" anchors, 10 per jamb

WINDSTORM RATINGS
Test Standards Test Rating
TAS 201 / ASTM E1886 / ASTM E1996 Impact Resistance 9 lb @ 50 ft/s
TAS 202 / ASTM E330 Static Pressure Resistance +75 / -65 psf
TAS 203 / ASTM E1886 / ASTM E1996 Cyclic Pressure Resistance +65 / -65 psf

AIR INFILTRATION RATINGS
Test Standards Test Pressure Infiltration Rate
TAS 202 / ASTM E283 1.57 psf     < 0.05 L/s-m2     
TAS 202 / ASTM E283 6.27 psf     < 0.05 L/s-m2     

WATER PENETRATION RATING
Test Standards Test Pressure Results
TAS 202 / ASTM E331 15 psf No Leakage

FORCED ENTRY RESISTANCE RATING
Test Standards Results
TAS 202 / AAMA 1304 Pass, No Entry
Listing Report Return to Search
Attributes
CriteriaASTM E331 (2000) (R2016)
CriteriaTAS 201 (1994)
CriteriaTAS 202 (1994)
CriteriaTAS 203 (1994)
CriteriaASTM E330 (2014) (R2021)
CriteriaASTM E283 (2004) R2012
CriteriaASTM E1996 (2017)
CriteriaASTM E1996 (2020)
CriteriaASTM E1886 (2019)
CriteriaASTM E1886 (2013a)
CSI Code08 11 00 Metal Doors and Frames
Listing SectionWINDSTORM - EXTERIOR DOORS
Spec ID63977
Design Documents
No Results
Public Documents
No Results