Product Covered:
Electric Power Door 3 Hour Swinging Flush Design Fire Door and Steel C-Channel Frame Assembly. This Door also has a Bullet Reistance rating so no modification can be conducted.
The assemblies as constructed below met UL-752 Bullet Resisting Equipment (2005 rev 2015) for Level 8 and SD-STD-01.01 Revision G (Amended) Certification Standard, Forced Entry and Ballistic Resistance of Structural Systems for 60 minutes.
Product Description:
Non-symmetrical, tube frame type (3/8” UL Level 7 plate and 14 gauge steel faces) swinging flush design fire door and steel channel frame assembly for installation singly or in pairs in 3 hour masonry applications in proprietary C6 x 8.2 steel C-channel frames.
Maximum Sizes - Doors:
Single-Swing |
Nominal 3’0” wide x nominal 7’0” high |
Standard Pairs |
Nominal 3'0” wide x nominal 7’0” high (Individual door leaf size not to exceed single swing limits above.) |
Double Egress Not Allowed
Door Thickness: 2.45" +/- 1/8"
Frames
Maximum Construction Opening (Pairs): 6’ 7” wide x 7’ 4” high
Maximum Construction Opening (Single): 3’ 6” wide x 7’ 4” high
Limitations:
Surface Vertical Rod (top and bottom latching), 3 point latching on single and 5 point latching on pair, Surface Mounted Multi-point Latching, Electric Power Door Custom Lever Operated Vertical Rod Latchset (top and bottom latching) Surface Mounted Closers, Surface Bolts, Surface Mounted Protection Plates.
Single Swing Latching Options:
Yale 314 dead lock and Yale NTS RemCore
Surface Vertical Rod (top and bottom latching and
Surface Mounted Rim Fire Exit Hardware (at standard height)*
Electric Power Door Custom Proprietary Lever Operated Vertical Rod Latchset (top and bottom latching) and latch into jamb at 1/3 height.
Deadlock (Cylindrical Yale 314 deadlock)
Standard Pair Latching Options (Minimum 5-point latching (top and bottom latching each leaf):
Surface Vertical Rod (top and bottom latching)
Surface Vertical Rod with Surface Mounted Flushbolts (top and bottom latching)
Electric Power Door Custom Lever Operated Vertical Rod Latchset (top and bottom latching)
Auxiliary Locking (Must be used in a combination with approved latching methods):
Deadlock (Cylindrical Yale 314 deadlock)
Steel astragals required for standard pairs.
Both singles and pairs require security rods (minimum 3/4” diameter x minimum 2-7/16" steel rods) for each door. Latch into door to door at 1/3 height.
.