Intertek Directory of Building Products

Jotul GF 370 DV MV Direct Vent Heater Company: Jøtul North America, Inc.

PRODUCT DESCRIPTION
Product Direct Vent Gas Fireplace
Brand Name Jotul
Description The model Jotul GF370 DV MV direct vent gas fireplace heater is a freestanding appliance. It is equipped and operated with a milivolt Pilot on Demand ignition system. The unit front and sides contain glass panels for viewing the flame and simulated wood logs.
The model GF370 DV MV Direct Vent Gas Room Heater is constructed of carbon steel firebox, with a cast iron outer shell. The GF370 DV MV is a free-standing stove that uses 4-inch by 6 5/8-inch co-axial venting. It is approved for use with snorkel vent components.
Models GF370 DV MV
Model Similarity None
Ratings 120V, 0.2A, 60 Hz (Blower)

APPLIANCE RATINGS
  NATURAL GAS PROPANE
Model GF370 DV MV
Orifice Size (0-2000 ft) #38 #53
Orifice Size (2000-4500 ft) #39 #53
Normal Input Rate (Btu/hr)(0-2000-ft) 28,000 24,000
Normal Input Rate (Btu/hr)(2000-4500-ft) 28,000 24,000
Manifold Pressure at Normal Input Rate (in.wc/kPa) 3.5/0.87 10.0/2.49
Minimum Input Rate (Btu/hr) 18,100 20,750
Manifold Pressure at Minimum Input Rate (in.wc/kPa) 1.6/0.40 6.4/1.59
Minimum Inlet Pressure (in.wc/kPa) 5.0/1.24 12.0/2.99

VENTING INFORMATION
Any combination of rise and run may be used if it is within the boundaries indicated below. The total vent length shall not exceed 35 feet. Refer to the Owner’s Manual for more details on the permissible venting configurations.
VENTING
Vent Type Coaxial vent
Vent Size 4” x 6 5/8”
Max. Vertical Length 35-feet
Min. Vertical Length 6-feet
Max. Horizontal Length 20-feet
Min. Horizontal Length 12-in
Max. Horizontal Length at Min. Vertical Length 6-in
Min. Vertical Length at Max. Horizontal Length 4-feet
Max. Number of Elbows 2-90°
 
VENT MANUFACTURERS
DuraVent GS
American Metal Products AmeriVent
Security Chimneys International, Ltd. Secure Vent
Selkirk Metalbestos Direct Temp
Metal-Fab, Inc. Sure-Seal Direct Vent
Industrial Chimney Corp. ExcelDirect
Bernard Dalsin Mfg. Pro Form
Olympia Chimney Supply, Inc. Ventis Direct Vent

CLEARANCES TO COMBUSTIBLE CONSTRUCTION
CLEARANCES
Rear (in/mm) 3/76
Sidewall (in/mm) (right) 7/178
Corner (in/mm) 5/127
Ceiling (in/mm) (from unit top) 16.75/425
 
VENTING SYSTEM CLEARANCES
Top of Horizontal Vent (in/mm) 2/51
Sides and Bottom of Horizontal Vent (in/mm) 1/25
Side of Vertical Vent (in/mm) 1/25
 
MINIMUM ALCOVE DIMENSIONS
Width (in/mm) 31.75/793
Height (in/mm) 62.25/1581
Depth (in/mm) 22.75/552
Listing Report Return to Search
Attributes
CriteriaCSA 2.17 Ed.4 (2017) (R2022)
CriteriaANSI Z21.88 / CSA 2.33 (2019) (R2024)
CSI Code10 30 00 Fireplaces and Stoves
Fuel TypePropane
Fuel TypeNatural Gas
Listing SectionVENTED GAS FIREPLACE HEATERS
Spec ID64671
Design Documents
No Results
Public Documents