Rite Door® by Adams Rite is a Hollow Metal Type (16, 18, 20 gauge) Vertically-Stiffened, Swinging Flush Design Fire Door for installation singly or in pairs, including double egress installed in labeled 14, 16 gauge steel frames in 20 minute to 3 hour locations greater than 650°F Temperature Rise at 30 minutes.
Model No. D3676 for same swing pairs
Model No. D3678 for double egress
Model No. D3375 & D3677 for single doors
Model D3680 – 20 minutes to 3 hours fire rated single swing, standard pair and double egress with Adams Rite Model 3681/82/83/84 Push/Pull devices. Doors larger than 8’0” require fire pin.
Limitations:
Hinges per NFPA-80, including fire rated continuous hinges, pocket pivot or offset pivots. Double Egress Pairs (10'0" wide x 10'0" high) up to 1-1/2 hour only.
Vision Light Kit - Maximum 1296 sq.in. for 20/45 minute; 100 sq.in. for 60/90 minute. If vision light kit uses technical glass products glass and accessories, the vision light kit sizes may be increased to meet T.G.P. listing (reference TGP listing for further details). Top latching only with no fire pin required for pairs and double egress.
Fire pins required when using Model Nos. D3677 & D3643 for single swing doors however fire pins are NOT required with Model No. D3375. No astragal required on pairs or double egress up to and including 3 hour fire doors.
Model D3680 – 20 minutes to 3 hours fire rated single swing, standard pair and double egress with Adams Rite Model 3681/82/83/84 Push/Pull devices. Doors larger than 8’0” require fire pin.
For Smoke & Draft Control assemblies ("S" Label) a positive pressure listed gasket shall be used. Stainless steel and PVC kickplates allowed up to 36" height. HPL skins may be applied to door faces. Hinge edge can be supplied with fire-rated power transfer devices.
| Configuration |
Maximum Size* |
| Single |
4'-0" wide x 10'-0" high (up to 3 hour)
5'0" wide x 10'0" high (up to 1-1/2 hour only) |
| Pairs |
8'-0" wide x 10'-0" high (up to 3 hour)
10'0" wide x 10'0" high (up to 1-1/2 hour only) |
| Double Egress |
8'-0" wide x 8'-0" high (up to 3 hour)
8'-0" wide x 10'-0" high (up to 1-1/2 hours only)
10'0" wide x 10'0" high (up to 1-1/2 hour only) |
Evaluated to the following...
This category includes doors evaluated without an edge-sealing system between the door and frame. It also includes doors evaluated with a sealing system incorporated (concealed or visible) into the edge of the door by the licensed manufacturer or machining distributor.
Meeting edges of pairs may require an astragal or an edge-sealing system. Please refer to individual door listings.
These doors are eligible for use in any "Category C - Standard" frame. These doors may also be installed in frames listed in "Category C - Proprietary" in the accordance with the frame manufacturer's individual listing.
All doors listed in Category A are eligible to bear the "S" (for Smoke & Draft Control assemblies) if a listed "Category H - Smoke & Draft Control Gasket" has been applied to the assembly. Please refer to Category H for individual gasket manufacturer's listings.
All doors in this category are identified by a label or marking bearing the wording, "Listed Fire Door", a time interval, a temperature rise rating, a serial number and the Warnock Hersey Certification Mark and "UBC-7-2-97/UL 10C".