Timberline Solar BIPV modules, Models TLS-1, TLS-1.1, TLS-1.2 and TLS-1.3 are building integrated photovoltaic roof coverings.The BIPV modules are used in conjunction with asphalt shingles complying with, and installed in accordance with, the applicable building code.
ROOF FIRE CLASSIFICATION: CLASS A - UL 790 and ASTM E108
Assembly Details |
Timberline Solar BIPV Modules |
Slope: |
Unlimited |
Deck Type: |
Combustible deck, min. 15/32-in. AC plywood or min. 7/16-in. OSB |
Details: |
1. One layer of minimum ASTM D226 Type I underlayment, or equivalent.
2. Timberline Solar building integrated photovoltaic roof covering.
Attachment and installation per GAF Energy installation instructions. |
Note: The component materials of the system must be applied in the order in which they are listed above.
CODE COMPLIANCE RESEARCH REPORT
Evaluation Method |
Building Codes |
Report No. |
IBC Chapter 15
IRC Chapter 9
FBC Chapter 15, including High-velocity Hurricane Zones |
2021, 2018 IBC
2021, 2018 IRC
2023, 2020 FBC |
CCRR-0456 |
FLORIDA PRODUCT APPROVAL
Report No. |
Product Covered |
FL No. 41599 |
Timberline Solar BIPV modules, Models TLS-1, TLS-1.1, TLS-1.2 and TLS-1.3 |