Intertek Directory of Building Products

Columbia 90 Minute Fire Rated Elevator Doors Company: Columbia Elevator, Inc.

ASSEMBLIES

Columbia 90 minute fire rated elevator door assemblies as noted below:
APPROVED  ASSEMBLIES
  MAXIMUM CLEARVIEW OPENING* NOMINAL DOOR PANEL SIZE** LABEL TYPE
TYPE WIDTH HEIGHT WIDTH DOOR/FRAME
  
CO 61.5 in. 120.75 in. 32 in. Standard Certification
 
2CO 121.5 in. 120.75 in. 32 in. Standard Certification
  
3CO 121.5 in. 120.75 in. 22 in. Standard Certification
  
CO 61.5 in. 168 in. 32 in. Oversize
  
2CO 121.5 in. 168 in. 32 in. Oversize
  
3CO 181.5 in. 168 in. 32 in. Oversize
*Smaller sizes (w x h) are allowed.
**Door height is dependent on overall assembly size.

KEY:
CO:Center Opening (2 Door Panels)
2CO: Two Speed Center Opening (4 Door Panels)
3CO: Three Speed Center Opening (6 Door Panels)

RATINGS
 
 Test Standard  Assembly  Rating
UL10B
NFPA 252
Elevator Door Assemblies (See Above)  90 Minute Neutral Pressure
 
LIMITATIONS
 Columbia elevator doors are limited to maximum opening sizes as shown in the table above.  Each door panel has a maximum size nominally 32" wide by 122" high (standard certification label applications).  [Taller doors are allowed for oversize applications as noted in the table above.] Installation must be into code compliant fire resistant rated structures (walls, sills, hardware) as contained in this listing.  [For drywall wall applications a 3 hour listed wall design must be used.  Installation in listed masonry walls is optional.]  Door and frame assemblies are to be marked with the Warnock Hersey certification label outlining the fire protection of the elevator doors. 
Listing Report Return to Search
Attributes
CriteriaUL 10(b) (2008) (R2015)
CriteriaNFPA 252 (2017)
CSI Code14 20 00 Elevators
Fire Resistance90 Min Neutral Pressure
Listing SectionELEVATOR DOOR/FRAME ASSEMBLIES
Spec ID65496
Design Documents
No Results
Public Documents
No Results