RC Industries dba Hirschberger 20 -180 Minute Steel Door Frame Company: RC Industries, Inc. dba Hirschberger - A Black Bear Co.

PRODUCT COVERED
RC Industries 20-180 Minute Positive Pressure Fire Rated Steel Door Frame (With Hose-Stream)

PRODUCT DESCRIPTION
Category C "Standard Frame" - Steel Door Frame for installation in steel or wood stud drywall or masonry openings for up to and including 180 minute fire protection durations.  Wall must be listed fire rated construction.

MAXIMUM SIZES
STANDARD FRAMES
Single Swing
Maximum Width: 48"
Maximum Height: 120"
Minimum Wall Thickness: 2"
Standard Pairs
Maximum Width: 96"
Maximum Height: 120"
Minimum Wall Thickness: 2"
Double Egress Pairs
NOT PERMITTED
DOOR WITH FIXED BAR TRANSOM
Single Swing
Maximum Width: 48"
Maximum Height: 120"
Maximum Transom Width: 48"
Maximum Transom Height: 32"
Minimum Wall Thickness: 4"
Standard Pairs
Maximum Width: 96"
Maximum Height: 120"
Maximum Transom Width: 96"
Maximum Transom Height: 32"
Minimum Wall Thickness: 4
These procedures apply to fire door frame assemblies which have demonstrated fire-resistive properties in fire tests sufficient to warrant their use with fire doors having a rating of 20 minutes up to and including 3 hours when tested in accordance with NFPA 252  Standard Methods of Fire Tests of Door Assemblies,  UL 10B Fire Tests of Door Assemblies, UL 10C Positive Pressure Tests of Door Assemblies, and CAN/ULC S104 Standard Method for Fire Tests of Door Assemblies. The frames may include provision for transoms with a fixed transom bar.
Listing Report Return to Search
Attributes
CriteriaUL 10(c) (2009) (R2015)
CriteriaCAN / ULC S104 (2015) (R2020)
CriteriaUL 10(b) (2008) (R2015)
CriteriaNFPA 252 (2017)
CSI Code08 11 00 Metal Doors and Frames
Fire Resistance3 Hour PP Category C Standard Frame
Fire Resistance3 Hour NP Fire Doorframe
Listing SectionCATEGORY C - STANDARD FRAMES
Lock PublisherOn
Spec ID66486
SwingSingle Swing
SwingStandard Pairs
SwingTransom
Design Documents