The Sunstyle BIPV Roofing Systems consists of active and inactive shingles installed over a batten and counterbatten system.
The active shingles are identified as Model M110 870 and are certified by Intertek for compliance with UL 7103. See the ETL Listed Mark Directory at intertek.com/directories.
The inactive shingles are ACM panels supplied by Sunstyle. The Alucobond panels are 4mm FR-core ACM panels manufactured by 3A Composites. The ACM panels are fabricated per job specifications and may be modified at the jobsite for penetrations.
The BIPV roofing system must be installed in accordance with the SunStyle Installation Manual attached to this specification as a Design Document.
MATERIAL RATINGS
| Test Standard |
Test Type |
Rating |
| FM 4473 |
Impact resistance |
Class 4 |
| ASTM D3161 |
Wind resistance |
Class F |
FIRE CLASSIFICATION - UL 790 CLASS A
| Slope: |
Min. 2:12 |
| Deck Type: |
Min. 15/32-in. AC grade Group 1 exterior plywood |
| Details: |
One layer RhinoRoof U20 underlayment
Fire-retardant-treated wood battens and counter battens per installation instructions
Model M110 870 PV panels and ACM panels installed per installation instructions |