Intertek Directory of Building Products

Jotul Model F35 Solid Fuel Room Heater - Safety Company: Jøtul North America, Inc.

PRODUCT DESCRIPTION
Product Solid Fuel Room Heater
Brand Name Jotul
Description A medium north /south loading adjustable-rate free standing non-catalytic wood heater employing a stepped baffle secondary combustion technology. The unit is composed of primarily a steel fire box and cast-iron exterior construction.
Baffle
  • Location: between top of combustion chamber and hearth
  • Restriction: 2.750 X 18.750 inches at the front of unit
  • Dimensions: covers the hearth area minus the restriction at front
  • Material: Stainless Steel, covered by ½ thick ceramic blanket
Firebox material
  • Firebrick 1 ¼ thick lining cover all sides and bottom
Flue gas exhaust
  • Location: Back
  • Dimensions: 6 inches
  • Material: Cast Iron
Gasket
  • Door: Fiberglass rope. 5/8” dia. Low density
  • Glass: Fiberglass rope. 1/4” dia. Low density
  • Refer to appendix 6 for all details and location
Overall unit dimension
  • Usable volume: 1.57 cuft.
  •  Refer to appendix 12 for volume calculation
  •  Overall heater dimension: 23-inch-wide 26.750-inch-deep 26.250 inch high
Models F35
Model Similarity None
Ratings None

CLEARANCES TO COMBUSTIBLE CONSTRUCTION
CLEARANCES
  Unprotected Surface Protected Surface
Side Rear of unit Corner Side Rear of unit Corner
Single wall connector 13-in
330-mm
14-in
356-mm
10-in
254-mm
4-in
101-mm
6-in
152-mm
4-in
101-mm
Double wall connector 13-in
330-mm
8-in
203-mm
9-in
229-mm
4-in
101-mm
6-in
152-mm
4-in
101-mm
Alcove
d/w connector
14-in
356-mm
19-in
483-mm
NA 6-in
152-mm
9-in
229-mm
NA
 
ALCOVE DIMENSIONS
Width (Min – DWC – unprotected surface) 50.25-in/1276 mm
Width (Min – DWC – protected surface) 34.25-in/870 mm
Height (Min – DWC – unprotected surface) 72-in/1829 mm
Height (Min – DWC – protected surface) 65-in/1651 mm
Depth (Max) 48-in/1219 mm

FLOOR PROTECTION REQUIREMENTS
Unit is acceptable for use on a combustible surface. A non-combustible protective cover must be placed a minimum of 16-inches from the front and 8-inches beyond both sides for the fueling door. Floor protection must extend 2-inches beyond each side of a horizontal chimney connector.
Listing Report Return to Search
Attributes
CriteriaUL 1482:2011
CriteriaCAN / ULC S627 (2023)
CSI Code10 30 00 Fireplaces and Stoves
Fuel TypeSolid Fuel - Wood
Listing SectionSOLID FUEL TYPE ROOM HEATERS
Spec ID67562
Design Documents
No Results
Public Documents
No Results