Stala Integrated Assemblies ICC-500 Solutions are ICC-500 (2020) tornado- and hurricane-resistant steel shelter swinging door and frame assemblies.
This listing is for wind pressure and impact resistance only. Fire resistance, when required by Section 603 of ICC 500-2020, is outside the scope of this listing. Assemblies required to be fire-resistance-rated shall also bear the label of a separate fire listing to the applicable standard(s).
In accordance with Section 507.3 of ICC 500-2020, operating hardware located on the unprotected side of the assembly shall be not susceptible to unintended unlatching by debris impact. Once engaged for storm shelter use, such operating hardware shall be locked, disabled, or inactive. Compliance with this requirement shall be confirmed by the Authority Having Jurisdiction.
Assembly
Type |
Permitted
Sizes |
Design Pressure |
Impact Rating |
Tornado |
Hurricane |
Single
Outswing
|
Frame:
Min: 36 in. × 82 in.
Max: 52-1/4 in. × 100 1/8 in.
Door:
Min: 31-13/16 in. × 79-5/8 in.
Max: 47-13/16 in.× 95-5/8 in. |
+291 psf
- 291 psf |
+233 psf
- 233 psf |
15-lb Missile
@ 100 mph |
Configuration |
Door: Stala-500 Door, 14-gauge
Frame: Stala-500 Frame,14-gauge
Latching Hardware: 3-point Concealed Vertical Rod with Horizontal Bottom Bolt:
-Securitech AutoBolt Max Model AWLCH-T Series
-Securitech 73TXX-IHD-HVL Series Exit Device
-Securitech 83TXX-IHD-HVL Series Exit Device
Hinges: Hager BB1199 Stainless Steel 4.5" x 4.5" or 5" x 4.5" heavy weight hinges installed with stainless steel screws. Minimum 3 hinges, 4 hinges required for doors over 80 inches in height.
Closer: LCN 4040XP Series For installation only without closer cover.
Door Position Switch: Schlage 679-05HM or similar up to 1" diameter.
Accessories Not Evaluated: Door Bottoms, Protection Plates, Door Viewers, Vision Kits, Weather Seals, Thresholds, Electric Power Transfers, Magnetic Locks. |