McKEON SafeSpace™ SS500X Series Tornado & Hurricane Resistant Door Company: McKEON Code Compliance Research Reports: CCRR-0500

McKEON SafeSpace™ SS500X Series Tornado & Hurricane Resistant Door

These ICC 500 ratings are for wind pressure and impact resistance only. Fire resistance, when required by Section 601 of ICC 500-2020, is outside the scope of this listing. Assemblies required to be fire-resistance-rated shall also bear the label of a separate fire listing to the applicable standard(s).

ICC-500-2020 STORM SHELTER RATINGSa, b
  Assembly Type     Permitted  Size   Design Pressure   Impact Rating  
Rolling
Tornado
Shelter Door
Min:
2'- 9-1/2" wide
3'- 6" high
 
Max:
20'-3-1/2" wide
22'-0" high
 
Tornado Design Pressure
+252/-252 psf  
15 lb @ 100 mph
Rolling
Hurricane
Shelter Door
Min:
2'- 9-1/2" wide
3'- 6" high

Max:
20'-3-1/2" wide
22'-0" high
Hurricane Design Pressure
+201 / -201 psf
15 lb @ 100 mph
aWidth is tip to tip of support guide angles
bAssemblies must be installed on the interior (protected) surface of the shelter wall with the barrel assembly protected.

HURRICANE GLAZED OPENING PROTECTION RATINGSa, b
 Test Standards    Maximum  Size  Design Pressure   Impact Rating  
TAS 201
TAS 202
TAS 203
DASMA 108
DASMA 115
20'-3-1/2" wide
22'-0" high
+120 / -120 psf 9 lb @ 80 ft/sec
aWidth is tip to tip of support guide angles
bAssemblies must be installed on the interior surface of the exterior envelope

FORCED ENTRY RESISTANCE RATINGa, b
Test Standard Maximum Size Rating
ASTM F3038 30'-0" wide
22'-0" high
60 Minutes
aWidth is tip to tip of support guide angles
bAssemblies must be installed on the protected (non-attack) face of the supporting wall

BULLET RESISTANCE RATINGa
Test Standard Rating
UL 752 (11th Edition) Level 1
aAssemblies must be installed on the protected (non-attack) face of the supporting wall

CODE COMPLIANCE RESEARCH REPORT
Evaluation Method Building Code CCRR Number
ICC 500
DASMA 108 and 115
TAS 201, 202, and 203
2024, 2021 IBC
2023, 2020 FBC
2022 CBC
2023 LABC
CCRR-0500            

INSTALLATION LIMITATIONS
When mounted to steel supporting structure, Mounting Angles are anchored with minimum  5/8" diameter A325 bolts spaced maximum 12 inches on-center. Structural adequacy of steel supporting structure is to be determined by others and is not evaluated as part of this Listing.

When mounted to concrete supporting structure, Mounting Angles are anchored with 5/8" diameter Simpson Strong-Bolt 2 wedge anchors spaced maximum 12 inches on-center.  The tested condition utilized 4000-psi strength concrete, an embedment length of 5-1/8 inches and an edge distance to the opening of 7-1/2 inches. Adequacy of concrete supporting structure is to be determined by others and is not evaluated as part of this Listing.

Alternate anchoring to supporting structure that maintains the maximum spacing of 12 inches on-center is to be designed by a registered design professional for pull-out and shear to resist the wind loads in accordance with ICC 500-2020 Section 304.

Installation shall follow these listing procedures and the manufacturer's instructions provided with each assembly. In the event of a conflict, these listing procedures govern.
Listing Report Certificate of Compliance Return to Search
Attributes
Certificate Date of ExpiryDecember 31, 2026
Certificate Date of Initial RegistrationFebruary 20, 2023
Certificate NumberWHI23-20384313
CriteriaTAS 201 (1994)
CriteriaTAS 202 (1994)
CriteriaTAS 203 (1994)
CriteriaUL 752 (2005) Ed: 11 (2015)
CriteriaICC 500 (2020)
CriteriaFEMA P-361 (2021) Ed.4
CriteriaASTM F3038 (2021)
CriteriaANSI / DASMA 115:2017
CriteriaANSI / DASMA 108:2017
CSI Code08 34 00 Special Function Doors
Listing SectionWIND LOAD RESISTANT DOORS
Spec ID67952